Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography
- 14 August 2014
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (1) , 279-284
Abstract
Comprehensive two-dimensional liquid chromatography is used to separate anionic, nonionic, and amphoteric surfactants by substance class, alkyl chain distribution, and degree of ethoxylation. A nearly orthogonal system with a hydrophilic interaction chromatography (HILIC) phase in the first and a reversed-phase material in the second dimension is applied to generate a separation with maximum peak capacity. The potential of the developed method is demonstrated by the reproducibility of retention time and peak area, which shows standard deviations less than 5 % and the analysis of real samples. An external calibration and the standard addition method were applied to determine unknown concentrations for the alkyl chain homologues of a betaine and for one ethoxylate (EO) homologue of a fatty alcohol ethoxylate in a sample mixture.Keywords
This publication has 21 references indexed in Scilit:
- Two‐dimensional chromatography of complex polymers, 8. Separation of fatty alcohol ethoxylates simultaneously by end group and chain lengthJournal of Separation Science, 2010
- Comprehensive liquid chromatography: Fundamental aspects and practical considerations—A reviewAnalytica Chimica Acta, 2009
- Quantification in Comprehensive Two-Dimensional Liquid ChromatographyAnalytical Chemistry, 2008
- Ultra rapid liquid chromatography as second dimension in a comprehensive two-dimensional method for the screening of pharmaceutical samples in stability and stress studiesJournal of Chromatography A, 2008
- Comprehensive two-dimensional liquid chromatography in analysis of Lamiaceae herbs: Characterisation and quantification of antioxidant phenolic acidsJournal of Chromatography A, 2007
- Comprehensive multi‐dimensional liquid chromatographic separation in biomedical and pharmaceutical analysis: a reviewBiomedical Chromatography, 2006
- Separation of branched polystyrene by comprehensive two-dimensional liquid chromatographyJournal of Chromatography A, 2006
- Multidimensional separation of peptides for effective proteomic analysisJournal of Chromatography B, 2005
- Comprehensive Two-Dimensional Normal-Phase (Adsorption)−Reversed-Phase Liquid ChromatographyAnalytical Chemistry, 2004
- One- and Two-Dimensional Chromatographic Analysis of Alcohol EthoxylatesAnalytical Chemistry, 1998