RESPIRE: A Spectral Kurtosis-Based Method to Extract Respiration Rate from Wearable PPG Signals
Open Access
- 1 July 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 84-89
Abstract
In this paper, we present the design of a wearable photoplethysmography (PPG) system, R-band for acquiring the PPG signals. PPG signals are influenced by the respiration or breathing process and hence can be used for estimation of respiration rate. R-Band detects the PPG signal that is routed to a Bluetooth low energy device such as a nearby-placed smartphone via microprocessor. Further, we developed an algorithm based on Extreme Learning Machine (ELM) regression for the estimation of respiration rate. We proposed spectral kurtosis features that are fused with the state-of the-art respiratory-induced amplitude, intensity and frequency variations-based features for the estimation of respiration rate (in units of breaths per minute). In contrast to the neural network (NN), ELM does not require tuning of hidden layer parameter and thus drastically reduces the computational cost as compared to NN trained by the standard backpropagation algorithm. We evaluated the proposed algorithm on Capnobase data available in the public domain.Keywords
All Related Versions
This publication has 23 references indexed in Scilit:
- Improving the Accuracy and Efficiency of Respiratory Rate Measurements in Children Using Mobile DevicesPLOS ONE, 2014
- Multiparameter Respiratory Rate Estimation From the PhotoplethysmogramIEEE Transactions on Biomedical Engineering, 2013
- Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer studyJournal of Clinical Monitoring and Computing, 2012
- Comparison of respiratory-induced variations in photoplethysmographic signalsPhysiological Measurement, 2010
- The spectral kurtosis: a useful tool for characterising non-stationary signalsMechanical Systems and Signal Processing, 2006
- The spectral kurtosis: application to the vibratory surveillance and diagnostics of rotating machinesMechanical Systems and Signal Processing, 2006
- The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triageAnnals of Emergency Medicine, 2005
- Sleep-Related Breathing Disorders and Risk of StrokeStroke, 2001
- Does This Patient Have Community-Acquired Pneumonia?JAMA, 1997
- Effect of Intrathoracic Pressure on Left Ventricular PerformanceThe New England journal of medicine, 1979