Constant-step stress accelerated life test of VFD under Weibull distribution case
Authors:
- 1 July 2005
- journal article
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 6 (7) , 722-727
Abstract
Constant-step stress accelerated life test of Vacuum Fluorescent Display (VFD) was conducted with increased cathode temperature. Statistical analysis was done by applying Weibull distribution for describing the life, and Least Square Method (LSM) for estimating Weibull parameters. Self-designed special software was used to predict the VFD life. Numerical results showed that the average life of VFD is over 30000 h that the VFD life follows Weibull distribution, and that the life-stress relationship satisfies linear Arrhenius equation completely. Accurate calculation of the key parameter enabled rapid estimation of VFD life.Keywords
This publication has 5 references indexed in Scilit:
- Statistical analysis of accelerated experiments in mechanics using a mechanical accelerated life model2003
- Improving the reliability of a newly-designed mobile phone by environmental tests and accelerated life tests2003
- A new model for step-stress testingIEEE Transactions on Reliability, 1998
- A least square estimation of three parameters of a Weibull distributionMicroelectronics Reliability, 1992
- Accelerated Life Testing - Step-Stress Models and Data AnalysesIEEE Transactions on Reliability, 1980