Laboratory Characterization of a Commercial Capacitance Sensor for Estimating Permittivity and Inferring Soil Water Content
- 1 August 2006
- journal article
- Published by Wiley in Vadose Zone Journal
- Vol. 5 (3) , 1048-1064
Abstract
Ring‐capacitor sensors are used widely for real‐time estimation of volumetric soil water content θ from measured resonant frequency f r , which is directly affected by the bulk soil permittivity ε. However, the relationship f r (ε) requires improved quantification. We conducted laboratory experiments to characterize the response of the Sentek EnviroSMART sensor system for a full range of ε values from air to water and a range of temperatures. Water–dioxane mixtures were placed into a solvent‐resistant container equipped with custom tools for heating and mixing the fluid, removing air bubbles from sensitive surfaces, measuring permittivity in situ, and creating an axisymmetric metal disturbance to the electric field. Total capacitance C was measured using a vector network analyzer (VNA) connected to one sensor, while four other sensors provided replicated f r readings. The measured temperature response of free water permittivity was linear with a negative slope, which is qualitatively consistent with theory. A precise nonlinear relationship between ε and normalized f r was derived. The instrumental error in ε was RMSE ε = 0.226 (for 3 < ε < 43), which corresponds to a measurement precision in θ(ε) derived from Topp's equation of RMSE θ = 0.0034 m 3 m −3 Axisymmetric numerical simulations of the electric field supplemented the experimental results. The characteristic length scale for the distance measured radially from the access tube is 12.5 mm, meaning that 80 and 95% of the signal are sensed within approximately 20 and 37 mm of the access tube, respectively. The results are crucial for scientific applications of the investigated sensor type to environmental media.Keywords
This publication has 24 references indexed in Scilit:
- Soil Profile Water Content Determination: Sensor Accuracy, Axial Response, Calibration, Temperature Dependence, and PrecisionVadose Zone Journal, 2006
- Cation and Water Content Effects on Dipole Rotation Activation Energy of SmectitesSoil Science Society of America Journal, 2004
- Soil Material, Temperature, and Salinity Effects on Calibration of Multisensor Capacitance ProbesSoil Science Society of America Journal, 2000
- A Complex Permittivity Measurement System for Undisturbed/Compacted SoilsGeotechnical Testing Journal, 1999
- Temperature effects on soil bulk dielectric permittivity measured by time domain reflectometry: A physical modelWater Resources Research, 1999
- Temperature effects on soil bulk dielectric permittivity measured by time domain reflectometry: Experimental evidence and hypothesis developmentWater Resources Research, 1999
- The sample areas of conventional and alternative time domain reflectometry probesWater Resources Research, 1998
- A numerical analysis of the effects of coatings and gaps upon relative dielectric permittivity measurement with time domain reflectometryWater Resources Research, 1997
- Spatial Averaging of Water Content by Time Domain Reflectometry: Implications for Twin Rod Probes with and without Dielectric CoatingsWater Resources Research, 1996
- A flow method for the measurement of the permittivity and dielectric loss factor of liquidsJournal of Physics E: Scientific Instruments, 1973