Suction Detection for the MicroMed DeBakey Left Ventricular Assist Device
Authors:
- Robert J. BenkowskiRBRobert J. Benkowski
- Gino F. MorelloGMGino F. Morello
- 1 July 2005
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 51 (4) , 321-328
Abstract
The MicroMed DeBakey Ventricular Assist Device (MicroMed Technology, Inc., Houston, TX) is a continuous axial flow pump designed for long-term circulatory support. The system received CE approval in 2001 as a bridge to transplantation and in 2004 as an alternative to transplantation. Low volume in the left ventricle or immoderate pump speed may cause ventricular collapse due to excessive suction. Suction causes decreased flow and may result in patient discomfort. Therefore, detection of this critical condition and immediate adaptive control of the device is desired. The purpose of this study is to evaluate and validate system parameters suitable for the reliable detection of suction. In vitro studies have been performed with a mock loop allowing pulsatile and nonpulsatile flow. Evidence of suction is clearly shown by the flow waveform reported by the implanted flow probe of the system. For redundancy to the implanted flow probe, it would be desirable to use the electronic motor signals of the pump for suction detection. The continuously accessible signals are motor current consumption and rotor/impeller speed. The influence of suction on these parameters has been investigated over a wide range of hydrodynamic conditions, and the significance of the respective signals individually or in combination has been explored. The reference signal for this analysis was the flow waveform of the ultrasonic probe. To achieve high reliability under both pulsatile and nonpulsatile conditions, it was determined that motor speed and current should be used concurrently for suction detection. Using the amplified differentiated current and speed signals, a suction-detection algorithm has been optimized, taking into account two different working points, defined by the value of the current input. The safety of this algorithm has been proven in vitro under pulsatile and nonpulsatile conditions over the full spectrum of possible speed and differential pressure variations. The algorithm described herein may be best utilized to provide redundancy to the existing flow based algorithm.Keywords
This publication has 12 references indexed in Scilit:
- Development of a Suction Detection System for Axial Blood PumpsArtificial Organs, 2004
- An Advanced Physiological Controller Design for a Left Ventricular Assist Device to Prevent Left Ventricular CollapseArtificial Organs, 2003
- TRANSIENT COMPUTATIONAL FLUID DYNAMICS STUDY OF AN AXIAL BLOOD PUMPASAIO Journal, 2003
- First successful Italian clinical experience with DeBakey VAD™The Journal of Heart and Lung Transplantation, 2001
- First Experiences with Outpatient Care of Patients with Implanted Axial Flow PumpsArtificial Organs, 2001
- Clinical experience with nine patients supported by the continuous flow Debakey VADThe Journal of Heart and Lung Transplantation, 2001
- Pulsatile Flow in Patients With a Novel Nonpulsatile Implantable Ventricular Assist DeviceCirculation, 2000
- Development and clinical application of the MicroMed DeBakey VADCurrent Opinion in Cardiology, 2000
- First Clinical Experience With the DeBakey VAD Continuous-Axial-Flow Pump for Bridge to TransplantationCirculation, 2000
- Ex Vivo Phase 1 Evaluation of the DeBakey/NASA Axial Flow Ventricular Assist DeviceArtificial Organs, 1996