Assessing the intra- and inter-reader reliability of dynamic ultrasound images in power Doppler ultrasonography
Authors:
- J M KoskiJKJ M Koski
- S SaarakkalaSSS Saarakkala
- M HelleMHM Helle
- U HakulinenUHU Hakulinen
- J O HeikkinenJHJ O Heikkinen
- H HermunenHHH Hermunen
- P BalintPBP Balint
- G A BruynGBG A Bruyn
- E FilippucciEFE Filippucci
- W GrassiWGW Grassi
- A IagnoccoAIA Iagnocco
- R LuosujärviRLR Luosujärvi
- 1 December 2006
- journal article
- research article
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 65 (12) , 1658-1660
Abstract
To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.Keywords
This publication has 14 references indexed in Scilit:
- Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipmentsAnnals of the Rheumatic Diseases, 2006
- Interobserver reliability of rheumatologists performing musculoskeletal ultrasonography: results from a EULAR “Train the trainers” courseAnnals of the Rheumatic Diseases, 2005
- Sonography of the Rotator Cuff: Analysis of Interobserver VariabilityAmerican Journal of Roentgenology, 2004
- Wrist joint involvement in systemic lupus erythematosus. An ultrasonographic study.2004
- Grey scale and power Doppler sonographic changes induced by intra-articular steroid injection treatmentAnnals of the Rheumatic Diseases, 2004
- Validation and reproducibility of ultrasonography in the detection of synovitis in the knee: A comparison with arthroscopy and clinical examinationArthritis & Rheumatism, 2004
- The value of sonography in the detection of bone erosions in patients with rheumatoid arthritis: A comparison with conventional radiographyArthritis & Rheumatism, 2000
- Comparison between clinical evaluation and ultrasonography in detecting hydrarthrosis of the knee.1999
- Sonography and magnetic resonance imaging equivalent for the assessment of full-thickness rotator cuff tearsArthritis & Rheumatism, 1999
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977