The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
Open Access
- 16 June 2021
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-7
Abstract
Background: The infra-acetabular screw which is placed from the pubis to the ischium can be used as a special positional screw of the posterior column of the acetabulum. This study was performed to simulate the surgical procedure and obtain the ideal insertion point, diameter, length and angle of the screw through the method of axial perspective in Chinese patients. Methods: We randomly collected the pelvic computed tomography (CT) scans of 200 adults. DICOM-formatted CT-scan images were imported into Mimics software to establish the 3D digital model of the right semi-pelvic was established. A virtual cylinder representing the screw was placed from the pubis to the ischium to fix the posterior column. The largest secure diameter and length of the virtual screw were measured and the position of the insertion point and the directions of the screw were also researched. Results: The screw insertion safe zone exhibits an irregular shape of “tear drop” in the reconstructed pelvic model. The mean maximum diameter of screws was 5.01 ± 1.28 mm, and the mean maximum length of screws was 93.99 ± 8.92 mm. The screw insertion corridor with the least diameter 3.5 mm was found in 94 of 100 males (94%) and 86 of 100 females (86%). We found gender-dependent differences for the mean maximum diameter and the maximum length of the screw. There was statistically significant difference between genders in the position of insertion point. Conclusions: In this study, we suggest an individual preoperative 3D reconstruction simulation to develop better screw placement plans, which provides a valuable guideline for seeking the largest secure corridor of infra-acetabular screw. Further biomechanical studies are needed to verify the function of the screw.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Percutaneous screw placement in acetabular posterior column surgery: Gender differences in implant positioningInjury, 2014
- Quadrilateral plate fractures of the acetabulum: An updateInjury, 2013
- Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric studyInternational Orthopaedics, 2012
- Fractures of the acetabulum in elderly patients: An updateInjury, 2012
- Screw- versus plate-fixation strength of acetabular anterior column fracturesJournal of Trauma and Acute Care Surgery, 2012
- Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertionArchives of orthopaedic and trauma surgery, 2012
- Infra-Acetabular Corridor—Technical Tip for an Additional Screw Placement to Increase the Fixation Strength of Acetabular FracturesJournal of Trauma: Injury, Infection & Critical Care, 2011
- Changes in the treatment of acetabular fractures over 15 years: Analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO/DGU)Injury, 2010
- The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fracturesThe Journal of Bone and Joint Surgery. British volume, 2005
- Screw fixation of acetabular fracturesInternational Orthopaedics, 2000