Accuracy of Pedicle Screw Placement with Robotic Guidance System
Authors:
- 1 December 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (24) , 1882-1889
Abstract
Study Design. A cadaveric study. Objective. To investigate the accuracy of pedicle screw placement using a robotic guidance system (RGS). Summary of Background Data. RGS is a unique surgery assistance-apparatus. Although several clinical studies have demonstrated that RGS provides accurate pedicle screw placement, very few studies have validated its accuracy. Methods. A total of 216 trajectories performed with the assistance of the RGS in eight cadavers were evaluated. The RGS was used, with different mounting platforms, to drill pilot holes in the thoracic and lumbosacral spine, using 3-mm diameter fiducial wires as trajectory markers. Deviation between the preoperative plan and executed trajectories was measured at the entry points to the vertebrae and at a depth of 30 mm along the wire. Both the deviation from the preoperative plan and the wire position were evaluated in the axial and sagittal planes using computed tomography (CT). Results. The average deviation from the planned wire placement was 0.64 ± 0.59 mm at the entry point and 0.63 ± 0.57 mm at a depth of 30 mm in the axial plane, and 0.77 ± 0.62 mm and 0.80 ± 0.66 mm, respectively, in the sagittal plane. The magnitude of deviation was not affected by the vertebral level or the platform used. The use of an open approach achieved greater screw placement accuracy at a depth of 30 mm in the sagittal plane, compared with the percutaneous approach. The fiducials were placed completely within the pedicle in 93.9% of trajectories in the axial plane (n = 164 pedicles with a width ≥5 mm) and 98.6% in the sagittal plane (n = 216). Conclusion. In this cadaveric study, RGS supported execution of accurate trajectories that were equal or slightly superior to reports of CT-based navigation systems. Level of Evidence: N/AKeywords
This publication has 41 references indexed in Scilit:
- Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle ScrewsSpine, 2012
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studiesEuropean Spine Journal, 2010
- Complications of Pedicle Screw Fixation in Scoliosis SurgerySpine, 2010
- Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic ScoliosisSpine, 2010
- Minimally invasive pedicle screw fixation utilizing O-arm fluoroscopy with computer-assisted navigation: Feasibility, technique, and preliminary resultsSurgical Neurology International, 2010
- Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilizationEuropean Spine Journal, 2006
- Miniature robotic guidance for spine surgery — introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centresThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist®The International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- The effect of transpedicular screw misplacement on late spinal stabilityActa Neurochirurgica, 2003