Reliability and validity of a new accelerometer (Wimu®) system for measuring velocity during resistance exercises
- 20 September 2017
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Vol. 232 (3) , 218-224
Abstract
This study had two main goals. The first was to determine the reliability of the Wimu® system (accelerometer) for mean velocity measurements during resistance exercises at 40% and 80% 1 repetition maximum (1RM). The second was to compare the results for the Wimu system to a linear encoder (gold standard) for mean velocity measurements when clipped to the bar during back squat exercises using the Smith machine. In all, 23 trained men (aged 22.3 ± 3.2 years) participated in this study. At maximum velocity in the concentric phase, they performed 10 repetitions with 40% 1RM and eight repetitions with 80% 1RM while using the Wimu system and T-Force linear encoder simultaneously to record data. Reliability was analysed using intraclass correlation, standard error of measurement and coefficient of variation. The validity was assessed using R2, intraclass correlation and Bland-Altman plots. The differences in test–retest reliability of both systems and systematic biases were non-significant ( p = 0.08–0.85) and very close to 0. The random errors averaged ±0.010 m/s. All the calculated coefficient of variations were less than 5% and all measurements had high intraclass correlations (mean: 0.936). Least-square linear regression and intraclass correlations for validity were very close to 1. Significant systematic biases were observed between the linear encoder and the Wimu system ( p < 0.001), although the effect sizes were small (0.21–0.44) and standard error of the estimate in concentric and eccentric phases at both intensities was less than 0.030. In conclusion, the findings of this study suggest that the Wimu system is a reliable and valid tool for the assessment of mean velocity during the back squat exercise using the Smith machine. These findings could help coaches and sport researchers evaluate athletes performing resistance exercises similar to squats with a reliable, valid and portable tool.Keywords
This publication has 26 references indexed in Scilit:
- The Importance of Movement Velocity as a Measure to Control Resistance Training IntensityJournal of Human Kinetics, 2011
- Validity of the Myotest® in Measuring Force and Power Production in the Squat and Bench PressJournal of Strength & Conditioning Research, 2011
- The reliability of linear position transducer, force plate and combined measurement of explosive power-time variables during a loaded jump squat in elite athletesSports Biomechanics, 2011
- Test–Retest Reliability of Barbell Velocity During the Free-Weight Bench-Press ExerciseJournal of Strength & Conditioning Research, 2011
- Effect of Instantaneous Performance Feedback During 6 Weeks of Velocity-Based Resistance Training on Sport-Specific Performance TestsJournal of Strength & Conditioning Research, 2011
- Squatting Kinematics and Kinetics and Their Application to Exercise PerformanceJournal of Strength & Conditioning Research, 2010
- Quantifying the Movement and the Influence of Load in the Back Squat ExerciseJournal of Strength & Conditioning Research, 2010
- Movement Velocity as a Measure of Loading Intensity in Resistance TrainingInternational Journal of Sports Medicine, 2010
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986