Passive Wireless Strain Sensors Using Microfabricated Magnetoelastic Beam Elements
Authors:
- 24 April 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 23 (6) , 1374-1382
Abstract
This paper describes resonant wireless strain sensors fabricated from magnetoelastic alloys. The transduction mechanism is the ΔE effect-the change in stiffness of magnetoelastic materials with applied strain or magnetic field. This is measured as a shift in the resonant frequency and is detected wirelessly using pick-up coils utilizing the magnetoelastic coupling of these materials. The sensors are fabricated from a 28-μm-thick foil of Metglas 2826 MB (Fe 40 Ni 38 Mo 4 B 18 ), a ferromagnetic magnetoelastic alloy, using microelectrodischarge machining. Two sensor types are described-single and differential. The single sensor has an active area of 7 × 2 mm 2 , excluding the anchors. At 23°C, it operates at a resonant frequency of 230.8 kHz and has a sensitivity of 13 × 10 3 ppm/mstrain; the dynamic range is 0.05-1.05 mstrain. The differential sensor includes a strain independent reference resonator of area 2 × 0.5 mm 2 in addition to a sensing element of area 2.5 × 0.5 mm 2 that is divided into two segments. The sensor resonance is at 266.4 kHz and reference resonance is at 492.75 kHz. The differential sensor provides a dynamic range for 0-1.85 mstrain with a sensitivity of 12.5 × 10 3 ppm/mstrain at 23°C. The reference resonator of the differential sensor is used to compensate for the temperature dependence of the Young's modulus of Metglas 2826 MB, which is experimentally estimated to be -524 ppm/°C. For an increment of 35°C, uncompensated sensors exhibit a resonant frequency shift of up to 42% of the dynamic range for the single sensor and 30% of the dynamic range of the differential sensor, underscoring the necessity of temperature compensation. The geometry of both types of sensors can be modified to accommodate a variety of sensitivity and dynamic range requirements.Keywords
Funding Information
- Food and Drug Administration, Department of Health and Human Services (2P50FD00378703)
This publication has 42 references indexed in Scilit:
- A passive, wireless strain sensor using a microfabricated magnetoelastic beam element2013
- Improving the Magnetoelectric Response of Laminates Containing High Temperature PiezopolymersIEEE Transactions on Magnetics, 2012
- Implantable Sensor Technology: From Research to Clinical PracticeJournal of the American Academy of Orthopaedic Surgeons, 2012
- A wireless strain sensor consumes less than 10 mWSmart Materials and Structures, 2011
- Tailored magnetoelastic sensor geometry for advanced functionality in wireless biliary stent monitoring systemsJournal of Micromechanics and Microengineering, 2010
- Magnetoelastic bending of Galfenol for sensor applicationsJournal of Applied Physics, 2005
- Environmental monitoring using magnetoelastic sensors2000
- Composite Terfenol-D sonar transducers1999
- Ferromagnetism1993
- Applications of amorphous metals: progress and prospects1983