Research on neutral surface of lightweight, horizontally supported mirror
Authors:
- 27 February 2018
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (02) , 025107-7
Abstract
The surface distortion due to gravity can be minimized when the flexure is located at the mirror’s neutral surface. When the mirror has relatively small surface curvature and simple lightweight structure, the location of neutral surface can be calculated by empirical formula or can approximately coincide with the mirror’s center of gravity. Otherwise, it is insufficient to determine the exact location of neutral surface. In addition, when the torque stiffness of flexure cannot be neglected, the optimum mount location may deviate from neutral surface and should be determined by more sophisticated analysis. The RMS surface distortions will degenerate significantly when the flexure has deviations from the optimum axial mount location due to fabrication and assembly errors. The distortion sensitivity to support axial location is critical to achieving low surface distortions in practice. We demonstrate a method of calculating the exact location of neutral surface and optimum mount location. The sensitivity of surface distortion to support axial location is theoretically calculated and compared with the results obtained from finite element analysis.Keywords
Funding Information
- National Natural Science Foundation of China (61705223)
This publication has 9 references indexed in Scilit:
- Adjustable bipod flexures for mounting mirrors in a space telescopeApplied Optics, 2012
- Study of bonding positions of isostatic mounts on a lightweight primary mirror2012
- Space active optics: performance of a deformable mirror for in-situ wave-front correction in space telescopes2012
- Extracting the zero-gravity surface figure of a mirror through multiple clockings in a flightlike hexapod mountApplied Optics, 2009
- Selective reinforcement of a 2m-class lightweight mirror for horizontal beam optical testing2008
- Three bipods slicer prototype: tests and finite element calculations2008
- Zernike Polynomial and Wavefront Fitting2006
- A small low-stress stable 3-DOF mirror mount with one arc-second tip/tilt resolution2004
- Optical Effect of Flexure in Vertically Mounted Precision MirrorsJournal of the Optical Society of America, 1954