Selection of prosthetic heart valves
- 1 November 2006
- journal article
- research article
- Published by Springer Nature in Current Treatment Options in Cardiovascular Medicine
- Vol. 8 (6) , 443-452
Abstract
Cardiovascular surgery for the repair or replacement of diseased heart valves has continually improved since its introduction in the early 1960s. Despite advances in prosthetic heart valve design, to date there is no valve that is comparable to the native human valve with respect to durability, risk of thrombosis, and overall hemodynamic function. Although bioprosthetic devices are similar to the native valve with respect to thrombogenicity, durability is a significant concern, particularly in younger patients. Approximately 45% of implanted bioprosthetic valves fail at 10 years. In contrast, mechanical prostheses have a significantly lower incidence of structural failure, with an implantation life of greater than 20 years, and are thus more often used for patients under the age of 65. Unfortunately, significant hemodynamic and thrombotic issues have yet to be resolved with the latest generation of mechanical valves. Thus, careful analysis of patient factors and valve-related complications must be considered when treatment of heart valve disease is offered to the patient. The purpose of this review is to discuss the current recommendations for surgical intervention for heart valve disease.Keywords
This publication has 35 references indexed in Scilit:
- Natural history of aortic valve stenosis of varying severity in the elderlyThe American Journal of Cardiology, 1996
- How should we manage symptomatic aortic stenosis in the patient who is 80 or older?Heart, 1995
- Comparison of outcome of asymptomatic to symptomatic patients older than 20 years of age with valvular aortic stenosisThe American Journal of Cardiology, 1988
- The effect of aortic valve replacement on survival.Circulation, 1982
- Severe aortic stenosis with impaired left ventricular function and clinical heart failure: results of valve replacement.Circulation, 1978
- Wall stress and patterns of hypertrophy in the human left ventricle.Journal of Clinical Investigation, 1975
- Natural History of Mitral Stenosis: A ReviewCirculation, 1972
- Aortic StenosisCirculation, 1968
- Systemic arterial embolism in rheumatic heart diseaseAmerican Heart Journal, 1951
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IAmerican Heart Journal, 1951