Second generation room-temperature dual-mode photodiodes with record-low uncertainties
Open Access
- 26 March 2026
- journal article
- Published by IOP Publishing in Metrologia
- Vol. 63 (2)
Abstract
The dual-mode method enables self-calibration of photodiodes by combining a photocurrent measurement with an electrical-substitution measurement of the absorbed optical power. Recent developments have focused on reducing thermal non-equivalence between optical and electrical heating, which limits accuracy through unwanted dependencies on beam position, power level and operating temperature. In this work, we present a new generation of dual-mode modules designed to improve thermal symmetry through a backside resistive heater, a redesigned thermal conduction path and an assembly approach optimised for manufacturability. The new design also facilitates the implementation of the dual-mode method with photodiodes based on materials other than silicon. We characterise the modules experimentally and with finite-element simulations. The measurements show a substantial reduction in position-dependent non-equivalence, from 230 ppm/mm for the previous generation to no significant dependency for the new generation. The measurements also reveal a clearly measurable dependence on optical power and relative temperature. These two effects are quantified and used to correct the apparent internal quantum deficiency (IQD). The resulting corrected IQD when measuring at the center of the diode with 748 μW optical power is -73 ppm ± 34 ppm (k = 1), consistent with simulations and representing the lowest uncertainty achieved with room-temperature dual-mode photodiodes to date. Remaining discrepancies between simulations and measurements highlight the need for improved thermal modelling, particularly regarding radiative coupling. The results demonstrate that the revised module design provides a robust pathway toward compact self-calibrating photodiodes with uncertainties equivalent to those of cryogenic radiometers.Keywords
Funding Information
- European Metrology Programme for Innovation and Research (22IEM06)
This publication has 8 references indexed in Scilit:
- Room temperature dual-mode internal quantum deficiency measurement with propagated uncertainty to 0.03% (k = 2)Metrologia, 2024
- Quantum yield in induced-junction silicon photodiodes at wavelengths around 400 nmMetrologia, 2024
- Long-term spectral responsivity stability of predictable quantum efficient detectorsMetrologia, 2022
- Dual-mode room temperature self-calibrating photodiodes approaching cryogenic radiometer uncertaintyMetrologia, 2022
- A detector combining quantum and thermal primary radiometric standards in the same artefactMetrologia, 2014
- Predictable quantum efficient detector: I. Photodiodes and predicted responsivityMetrologia, 2013
- Reflectance calculations for a predictable quantum efficient detectorMetrologia, 2009
- Trap Detectors and their PropertiesMetrologia, 1991