W5″ Test: A simple method for measuring mean power output in the bench press exercise
- 27 May 2016
- journal article
- research article
- Published by Wiley in European Journal of Sport Science
- Vol. 16 (8) , 940-947
Abstract
The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86–0.94; p < .01) and detecting training-induced changes (R2: 0.78). Good to excellent intra-tester (intraclass correlation coefficient (ICC) range: 0.81–0.97) and excellent inter-tester (ICC range: 0.96–0.99; coefficient of variation range: 2.4–4.1%) reliability was found for all loads. The W5″ Test was shown to be a valid, reliable and sensitive method for measuring mean power output during the bench press exercise in subjects who have previous resistance training experience.Keywords
This publication has 22 references indexed in Scilit:
- The Reliability of Linear Position Transducer and Force Plate Measurement of Explosive Force–Time Variables During a Loaded Jump Squat in Elite AthletesJournal of Strength & Conditioning Research, 2011
- Test–Retest Reliability of Barbell Velocity During the Free-Weight Bench-Press ExerciseJournal of Strength & Conditioning Research, 2011
- Effect of Instantaneous Performance Feedback During 6 Weeks of Velocity-Based Resistance Training on Sport-Specific Performance TestsJournal of Strength & Conditioning Research, 2011
- Functional Performance, Maximal Strength, and Power Characteristics in Isometric and Dynamic Actions of Lower Extremities in Soccer PlayersJournal of Strength & Conditioning Research, 2009
- Total Body Water Measurements in Adolescent Athletes: A Comparison of Six Field Methods With Deuterium DilutionJournal of Strength & Conditioning Research, 2009
- A Metronome for Controlling the Mean Velocity During the Bench Press ExerciseJournal of Strength & Conditioning Research, 2009
- Assessing the Force-Velocity Characteristics of the Leg Extensors in Well-Trained Athletes: The Incremental Load Power ProfileJournal of Strength & Conditioning Research, 2008
- Does an Optimal Load Exist for Power Training?Strength & Conditioning Journal, 2008
- Effects of dynamic resistance training on fascicle lengthand isometric strengthJournal of Sports Sciences, 2006
- Age differences in knee extension power, contractile velocity, and fatigabilityJournal of Applied Physiology, 2005