Comparison of broadband and ultrabroadband pulses at MHz and GHz pulse‐repetition rates for nonlinear femtosecond‐laser scanning microscopy
- 17 December 2010
- journal article
- research article
- Published by Wiley in Journal of Biophotonics
- Vol. 4 (1-2) , 84-91
Abstract
Nonlinear optical imaging of human skin and of polychromatic microspheres was carried out to compare and evaluate the imaging properties of three different excitation femtosecond lasers: a spectrally tunable 80 MHz Ti: sapphire oscillator that produced 100 fs pulses (spectral width ∼10 nm) and two ultrabroadband Ti: sapphire oscillators with repetition rates of 85 MHz and 1 GHz. The latter of these two and the 100 fs laser were combined with a laser scanning microscope (TauMap). The intensities of images of the polychromatic microsphere samples obtained with both lasers are in accordance with the usual dependence of two‐photon processes on laser pulse parameters, i.e. the intensity is proportional to the square of the mean laser power and the reciprocal pulse duration. In contrast to that, skin images measured with all three different excitation sources with mean powers of each laser adjusted to the particular pulse length and repetition rate exhibited discrepancies from this relation. For characterization of the ultrabroadband GHz laser, the measurements are supplemented by spectra of second‐harmonic‐generation signals of urea and collagen.Keywords
This publication has 25 references indexed in Scilit:
- Sensitivity and Specificity of Multiphoton Laser Tomography for In Vivo and Ex Vivo Diagnosis of Malignant MelanomaJournal of Investigative Dermatology, 2009
- Spectral fluorescence lifetime detection and selective melanin imaging by multiphoton laser tomography for melanoma diagnosisExperimental Dermatology, 2009
- In vitroandin vivoimaging of xenobiotic transport in human skin and in the rat liverJournal of Biophotonics, 2008
- Optical knock out of stem cells with extremely ultrashort femtosecond laser pulsesJournal of Biophotonics, 2008
- Multiphoton tissue imaging using high‐NA microendoscopes and flexible scan heads for clinical studies and small animal researchJournal of Biophotonics, 2008
- Clinical multiphoton tomographyJournal of Biophotonics, 2008
- Compact multiphoton/single photon laser scanning microscope for spectral imaging and fluorescence lifetime imagingScanning, 2004
- Real-time second-harmonic-generation microscopy based on a 2-GHz repetition rate Ti:sapphire laserOptics Express, 2003
- High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolutionJournal of Biomedical Optics, 2003
- Two-Photon Laser Scanning Fluorescence MicroscopyScience, 1990