Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System
Authors:
Open Access
- 24 September 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (6) , 1091-1098
Abstract
We present a noncontact method to monitor blood oxygen saturation (SpO 2 ). The method uses a CMOS camera with a trigger control to allow recording of photoplethysmography (PPG) signals alternatively at two particular wavelengths, and determines the SpO 2 from the measured ratios of the pulsatile to the nonpulsatile components of the PPG signals at these wavelengths. The signal-to-noise ratio (SNR) of the SpO 2 value depends on the choice of the wavelengths. We found that the combination of orange (λ = 611 nm) and near infrared (λ = 880 nm) provides the best SNR for the noncontact video-based detection method. This combination is different from that used in traditional contact-based SpO 2 measurement since the PPG signal strengths and camera quantum efficiencies at these wavelengths are more amenable to SpO 2 measurement using a noncontact method. We also conducted a small pilot study to validate the noncontact method over an SpO 2 range of 83%-98%. This study results are consistent with those measured using a reference contact SpO 2 device (r = 0.936, p <; 0.001). The presented method is particularly suitable for tracking one's health and wellness at home under free-living conditions, and for those who cannot use traditional contact-based PPG devices.Keywords
Funding Information
- National Science Foundation
This publication has 24 references indexed in Scilit:
- Non-contact estimation of heart rate and oxygen saturation using ambient lightBiomedical Optics Express, 2014
- Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of SkinIEEE Transactions on Circuits and Systems for Video Technology, 2014
- Non-contact video-based vital sign monitoring using ambient light and auto-regressive modelsPhysiological Measurement, 2014
- Non-contact detection of oxygen saturation based on visible light imaging device using ambient lightOptics Express, 2013
- Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exerciseJournal of Biomedical Optics, 2011
- Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetryReview of Scientific Instruments, 2007
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- Pulse Oximetry Theory and Calibration for Low SaturationsIEEE Transactions on Biomedical Engineering, 2004
- Design of Pulse Oximeters1997
- Multiple scattering effect in transmission pulse oximetryMedical & Biological Engineering & Computing, 1995