Assessment of mold infestation of conditioning devices and indoor air
- 31 July 2021
- journal article
- research article
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 100 (7) , 668-673
Abstract
Introduction. Indoor air quality is an essential component of a healthy human environment. Air conditioning units can affect indoor air quality, including mycogenic contamination of the air if the condition is not adequately monitored. Material and method. The paper presents the results of a mycological study of air samples and flushes from the surface of filters and gratings of air conditioning devices taken from 40 residential and office premises. Results. The presence of micromycetes fungi was noted in 100% of the samples taken from the surface of filters and air conditioning grids and 81.6% of air samples. A greater species diversity of fungi (26 species) was revealed in air samples compared to air conditioning devices (15 species). A higher frequency of occurrence of dark-coloured species of fungi, incl. Aspergillus spp. and Alternaria spp., and fungal species belonging to the third group of pathogenicity, were noticed on the surface of air conditioners, compared with air samples, in which Penicillium spp., Fusarium spp., Trichoderma spp. were more often detected. It was found that the surface of air conditioners functioned sporadically. For a short time (28 rooms), there is a large species diversity of mycobiota at a low or moderate level of seeding (no more than 103 CFU). In rooms with long-term continuous air conditioners (12 rooms), a high level of seeding (more than 104 CFU) by 1-2 species of fungi was more often noted. The existence of a close relationship, confirmed by the values of the Pearson contingency coefficient, between the species composition of the mycobiota of air conditioning devices and air, and a higher level of mycogenic contamination in rooms with long-term continuous operation of air conditioners, were shown. Conclusion. Thus, air conditioning devices can be a source of mycogenic air contamination, especially during long-term continuous operation, which must be taken into account to ensure indoor air quality.Keywords
This publication has 22 references indexed in Scilit:
- Indoor exposure levels of bacteria and fungi in residences, schools, and offices in China: A systematic reviewIndoor Air, 2020
- Exposure to indoor air contaminants in school buildings with and without reported indoor air quality problemsEnvironment International, 2020
- Associations between household airborne culturable fungi and allergies and airway illnesses in childhood in Shanghai, ChinaEnvironmental Science and Pollution Research, 2020
- Air Microbiome and Pollution: Composition and Potential Effects on Human Health, Including SARS Coronavirus InfectionJournal of Environmental and Public Health, 2020
- Bioburden Assessment by Passive Methods on a Clinical Pathology Service in One Central Hospital from Lisbon: What Can it Tell Us Regarding Patients and Staff Exposure?Atmosphere, 2020
- Exploiting the Advantages of Molecular Tools for the Monitoring of Fungal Indoor Air Contamination: First Detection of Exophiala jeanselmei in Indoor Air of Air-Conditioned OfficesMicroorganisms, 2019
- MYCOBIOTA OF SOILS OF URBAN TERRITORIES WITH DIFFERENT LEVELS OF ANTHROPOGENIC LOADHygiene and sanitation, 2019
- Seasonal diversity of biodeteriogenic, pathogenic, and toxigenic constituents of airborne mycobiota in a sacral environmentArchives of Industrial Hygiene and Toxicology, 2018
- Indicators of airborne fungal concentrations in urban homes: Understanding the conditions that affect indoor fungal exposuresScience of The Total Environment, 2015
- Molds, mycotoxins, and sick building syndromeToxicology and Industrial Health, 2009