Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function
- 20 January 2016
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (2) , 366-374
Abstract
Purpose: To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady‐state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes.Materials and Methods: LV short axis stacks of two compressed sensing breath‐hold cine sequences with high spatial resolution (SPARSE‐SENSE HS: temporal resolution: 40 msec, in‐plane resolution: 1.0 × 1.0 mm2) and high temporal resolution (SPARSE‐SENSE HT: temporal resolution: 11 msec, in‐plane resolution: 1.7 × 1.7 mm2) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in‐plane resolution: 1.7 × 1.7 mm2) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t‐test, Bland–Altman plots, and Passing–Bablock regression.Results: Small differences were observed between standard SSFP and SPARSE‐SENSE HS for stroke volume (SV; −7 ± 11 ml; P = 0.024), ejection fraction (EF; −2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end‐diastolic volume (EDV; P = 0.079) and end‐systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE‐SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland–Altman analysis showed good agreement between the sequences (maximum bias ≤ −8%).Conclusion: Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366–374.Keywords
This publication has 13 references indexed in Scilit:
- Compressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and MassJACC: Cardiovascular Imaging, 2014
- Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSEMagnetic Resonance in Medicine, 2012
- ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESCEuropean Heart Journal, 2012
- Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routineEuropean Radiology, 2010
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Normalized Left Ventricular Systolic and Diastolic Function by Steady State Free Precession Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2006
- The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failureJACC, 2003
- Comparison of Techniques for the Measurement of Left Ventricular Function Following Cardiac TransplantationJournal of Cardiovascular Magnetic Resonance, 2002
- Which standard has the gold?JACC, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986