Comparison of outcomes of conventional WaveLight® Allegretto Wave® and Technolas® excimer lasers in myopic laser in situ keratomileusis
Authors:
Open Access
- 1 July 2012
- journal article
- case report
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 6, 1159-1168
Abstract
Objective: To compare the results of laser in situ keratomileusis for myopia using WaveLight® Allegretto Wave® Eye-Q® and Technolas® 217z excimer lasers. Method: A retrospective, comparative case series of 442 eyes matched for age and myopia: half each were treated with Allegretto's wavefront-optimized algorithm and Technolas PlanoScan. Outcome measures were postoperative mean logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity (UCVA), manifest refraction spherical equivalent (MRSE), cylinder, safety and efficacy indices, refractive predictability, and optical zone size selection. Refractive predictability of a subgroup treated for –2.50 to –4.0 diopter (D) was analyzed separately. Results: At mean follow-up of 80.5 days, mean logMAR UCVA, mean MRSE and mean postoperative cylinder were 0.02 ± 0.07 (range –0.12 to 0.30), 0.27 ± 0.36 D (range –1.25 to 1.50 D) and –0.33 ± 0.30 D (range 0.00 to –1.50 D) for Allegretto versus 0.02 ± 0.08 (range –0.12 to 0.40), 0.095 ± 0.47 D (range –1.25 to 1.13 D) and –0.44 ± 0.5 2 D (range 0.00 to –2.25 D) for Technolas (P = 0.98, 0.80 and 0.006). Mean safety and efficacy indices were 1.05 ± 0.13 (0.75–1.33) and 0.97 ± 0.13 (0.50–1.33) for Allegretto and 1.07 ± 0.14 (0.75–1.49) and 0.97 ± 0.17 (0.40–1.49) for Technolas (P = 0.23 and 0.69). Proportions of eyes achieving postoperative MRSE within ±1.0 D, ±0.5 D, and ±0.25 D were 98.2%, 91.9% and 75.6% for Allegretto and 99.1%, 97.8% and 72.4% for Technolas (P = 0.68, 0.20 and 0.51). Mean optical zone size selected was 6.48 ± 0.10 mm (range 6.0–6.5 mm) for Allegretto and 6.38 ± 0.19 mm (range 5.6–6.6 mm) for Technolas (P < 0.001). Of the subgroup with treatment between –2.5 and –4.0 D, 86.8% and 58.5% of eyes treated with Allegretto achieved postoperative MRSE within ±0.50 D and ±0.25 D versus 70.4% and 44.4% for Technolas (P = 0.006 and 0.057). Conclusion: No differences were seen in postoperative mean logMAR UCVA, MRSE, safety and efficacy indices between the two lasers. Allegretto produced less residual astigmatism, possibly improved refractive predictability, and required smaller optical zone selection.Keywords
This publication has 27 references indexed in Scilit:
- LASIK for Mixed Astigmatism Using the ALLEGRETTO WAVE: 3- and 6-Month Results with the 200- and 400-Hz PlatformsJournal of Refractive Surgery, 2010
- A 10-Year Prospective Audit of LASIK Outcomes for Myopia in 37932 Eyes at a Single Institution in AsiaOphthalmology, 2010
- Femtosecond laser in laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2010
- Comparing Conventional and Wavefront-optimized LASIK for the Treatment of HyperopiaJournal of Refractive Surgery, 2010
- Comparison of the Femtosecond Laser and Mechanical Keratome for Laser In Situ KeratomileusisArchives of Ophthalmology (1950), 2008
- A Retrospective Comparison of LASIK Outcomes for Myopia and Myopic Astigmatism With Conventional NIDEK Versus Wavefront-guided VISX and Alcon PlatformsJournal of Refractive Surgery, 2008
- Retrospective comparison of 3 laser platforms to correct myopic spheres and spherocylinders using conventional and wavefront-guided treatmentsJournal of Cataract & Refractive Surgery, 2007
- Five year follow up of laser in situ keratomileusis for all levels of myopiaBritish Journal of Ophthalmology, 2006
- Six-year follow-up of laser in situ keratomileusis for moderate and extreme myopia using a first-generation excimer laser and microkeratomeJournal of Cataract & Refractive Surgery, 2003
- Laser in situ keratomileusis with a scanning excimer laser for the correction of low to moderate myopia with and without astigmatismJournal of Cataract & Refractive Surgery, 2001