Abstract
This work proposes a new framework for measuring sternal cardio-mechanical signals from moving subjects using multiple sensors. An array of inertial measurement units (IMUs) are attached to the chest wall of subjects to measure the seismo-cardiogram (SCG) from accelerometers and the gyro-cardiogram (GCG) from gyroscopes. A digital signal processing method based on constrained independent component analysis is applied to extract the desired cardio-mechanical signals from the mixture of vibration observations. Electrocardiogram (ECG) and photoplethysmography (PPG) modalities are evaluated as reference sources for the constrained independent component analysis algorithm. Experimental studies with fourteen young, healthy adult subjects demonstrate the feasibility of extracting seismo- and gyro-cardiogram signals from walking and jogging subjects, with speeds of 3.0 miles per hour and 4.6 miles per hour, respectively. Beat-to-beat and ensemble-averaged features are extracted from the outputs of the algorithm. The beat-to-beat cardiac interval results demonstrate average detection rates of 91.44% during walking and 86.06% during jogging from SCG, and 87.32% during walking and 76.30% during jogging from GCG. The ensemble-averaged pre-ejection period (PEP) calculation results attained overall squared correlation coefficients of 0.9048 from SCG and 0.8350 from GCG with reference PEP from impedance cardiogram (ICG). Our results indicate that the proposed framework can improve the motion tolerance of cardio-mechanical signals in moving subjects. The effective number of recordings during day time could be potentially increased by the proposed framework, which will push forward the implementation of cardio-mechanical monitoring devices in mobile healthcare.Keywords
Funding Information
- Ignition Grant Initiative from Stevens Institute of Technology
This publication has 35 references indexed in Scilit:
- Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial?Healthcare Informatics Research, 2015
- Ballistocardiography and Seismocardiography: A Review of Recent AdvancesIEEE Journal of Biomedical and Health Informatics, 2014
- Automatic Annotation of Seismocardiogram With High-Frequency Precordial AccelerationsIEEE Journal of Biomedical and Health Informatics, 2014
- Precordial Vibrations Provide Noninvasive Detection of Early-Stage HemorrhageShock, 2014
- Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic MonitoringThe American Journal of Medicine, 2014
- Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjectsAutonomic Neuroscience, 2013
- Morphologically constrained ICA for extracting weak temporally correlated signalsNeurocomputing, 2008
- ICA with ReferenceNeurocomputing, 2006
- Usefulness of Seismocardiography for the Diagnosis of Ischemia in Patients with Coronary Artery DiseaseAnnals of Noninvasive Electrocardiology, 2005
- Methodological Guidelines for Impedance CardiographyPsychophysiology, 1990