Region-of-interest diffuse optical tomography system
- 1 January 2016
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (1) , 013701
Abstract
Diffuse optical tomography (DOT) using near-infrared light is a promising tool for non-invasive imaging of deep tissue. This technique is capable of quantitative reconstruction of absorption (μa) and scattering coefficient (μs) inhomogeneities in the tissue. The rationale for reconstructing the optical property map is that the absorption coefficient variation provides diagnostic information about metabolic and disease states of the tissue. The aim of DOT is to reconstruct the internal tissue cross section with good spatial resolution and contrast from noisy measurements non-invasively. We develop a region-of-interest scanning system based on DOT principles. Modulated light is injected into the phantom/tissue through one of the four light emitting diode sources. The light traversing through the tissue gets partially absorbed and scattered multiple times. The intensity and phase of the exiting light are measured using a set of photodetectors. The light transport through a tissue is diffusive in nature and is modeled using radiative transfer equation. However, a simplified model based on diffusion equation (DE) can be used if the system satisfies following conditions: (a) the optical parameter of the inhomogeneity is close to the optical property of the background, and (b) μs of the medium is much greater than μa (μs > > μa). The light transport through a highly scattering tissue satisfies both of these conditions. A discrete version of DE based on finite element method is used for solving the inverse problem. The depth of probing light inside the tissue depends on the wavelength of light, absorption, and scattering coefficients of the medium and the separation between the source and detector locations. Extensive simulation studies have been carried out and the results are validated using two sets of experimental measurements. The utility of the system can be further improved by using multiple wavelength light sources. In such a scheme, the spectroscopic variation of absorption coefficient in the tissue can be used to arrive at the oxygenation changes in the tissue.Keywords
This publication has 16 references indexed in Scilit:
- Light Propagation in NIR Spectroscopy of the Human BrainIEEE Journal of Selected Topics in Quantum Electronics, 2014
- Accelerated gradient based diffuse optical tomographic image reconstructionMedical Physics, 2010
- Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performanceJournal of Biomedical Optics, 2010
- Phase-encoded retinotopy as an evaluation of diffuse optical neuroimagingNeuroImage, 2010
- Diffuse optical tomography through solving a system of quadratic equations: theory and simulationsPhysics in Medicine & Biology, 2006
- Gauss–Newton method for image reconstruction in diffuse optical tomographyPhysics in Medicine & Biology, 2005
- Three-dimensional diffuse optical tomography of bones and jointsJournal of Biomedical Optics, 2002
- Quantitative Hemoglobin Tomography with Diffuse Near-Infrared Spectroscopy: Pilot Results in the BreastRadiology, 2001
- Gradient-based iterative image reconstruction scheme for time-resolved optical tomographyIEEE Transactions on Medical Imaging, 1999
- Experimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomographyOptics Letters, 1995