The RIC Arm—A Small Anthropomorphic Transhumeral Prosthesis
Authors:
Open Access
- 10 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (6) , 2660-2671
Abstract
Recent advances in motor and gear designs have accelerated the development of multi-degree of freedom prosthetic limbs controlled by novel electromyographic signal processing techniques. Most of these new devices have focused on improved performance at the expense of other critical factors for clinical use, such as weight and bulk, which significantly affect cosmesis and comfort. This paper presents the mechatronic design of an anthropomorphic transhumeral prosthetic arm-the Rehabilitation Institute of Chicago (RIC) arm-that is small enough for a 25th percentile female and weighs only 1518 g. Specifically, we describe the design of the RIC arm, including the integration of custom external rotor motors, cycloid transmissions, nonbackdrivable clutches, and custom pattern recognition control. Mechanics and control performance of the RIC arm were evaluated within the laboratory, and clinical viability was preliminary evaluated during a take-home field trial by an individual with a transhumeral amputation.Keywords
Funding Information
- U.S. Department of War (W81XWH-10-2-0033, W81XWH-11-1-0720)
- Canada Natural Sciences and Engineering Research Council (RGPIN 2014-06464)
This publication has 41 references indexed in Scilit:
- Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2015
- Dynamics Analysis of Cycloidal Speed Reducers With Pinwheel and Nonpinwheel DesignsJournal of Mechanical Design, 2014
- Motion Normalized Proportional Control for Improved Pattern Recognition-Based Myoelectric ControlIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2013
- A Bus-Based Smart Myoelectric Electrode/Amplifier—System RequirementsIEEE Transactions on Instrumentation and Measurement, 2011
- Unified Approach to Cycloid Drive Profile, Stress, and Efficiency OptimizationJournal of Mechanical Design, 2010
- A comprehensive study on capabilities and limitations of roller–screw with emphasis on slip tendencyMechanism and Machine Theory, 2009
- SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics2008
- General Concepts of Wrist Biomechanics and a View from Other SpeciesJournal of Hand Surgery (European Volume), 2008
- A protocol for clinical evaluation of the carrying angle of the elbow by anatomic landmarksJournal of Shoulder and Elbow Surgery, 2008
- Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: Normative data, reliability, and validityArchives of Physical Medicine and Rehabilitation, 2002