A screening method for the simultaneous detection of glucocorticoids, diuretics, stimulants, anti-oestrogens, beta-adrenergic drugs and anabolic steroids in human urine by LC-ESI-MS/MS
- 14 August 2008
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 392 (4) , 681-698
Abstract
This paper presents a general screening method, based on liquid chromatography/mass spectrometry (LC/MS), for the simultaneous detection in human urine of 72 xenobiotics (21 diuretics, 16 synthetic glucocorticoids, 17 beta-adrenergic drugs, 10 stimulants, 5 anti-oestrogens and 3 anabolic steroids), excreted free or as glucuro-conjugates in urine. Although the method has been specifically designed and evaluated in view of its potential application to anti-doping analyses, it can also be effective in other areas of analytical toxicology. Sample preparation was based on two liquid/liquid separation steps (performed at alkaline and at acid pH, respectively) of hydrolyzed human urine, and then an assay by LC/MS-MS in positive and negative ionization mode using an electrospray ionization source (ESI) and multiple reaction monitoring (MRM) as the acquisition mode. The overall time needed for an LC run was less than 15 minutes. All compounds showed good reproducibility in terms of both the retention times (CV%<1) and the relative abundances of the diagnostic transitions (CV%<10). The limits of detection (LOD) were in the range of 1–50 ng/mL for glucocorticoids, anti-oestrogens and steroids, and 50–500 ng/mL for diuretics, beta-adrenergic drugs and stimulants, thus satisfying the minimum required performance limits (MRPL) set by the World Anti-Doping Agency (WADA) for the accredited anti-doping laboratories.Keywords
This publication has 14 references indexed in Scilit:
- Preventive doping control analysis: liquid and gas chromatography time‐of‐flight mass spectrometry for detection of designer steroidsRapid Communications in Mass Spectrometry, 2007
- A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometryAnalytica Chimica Acta, 2007
- Analytik modifizierter Steroidhormone mittels Flüssigkeitschromatographie/Tandem-Massenspektrometrie Analysis of modified steroid hormones using liquid chromatography/tandem mass spectrometryJournal of Laboratory Medicine, 2006
- Rapid screening method for diuretics in doping control using automated solid phase extraction and liquid chromatography-electrospray tandem mass spectrometryAnalytica Chimica Acta, 2004
- Sports drug testing ? an analyst's perspectiveChemical Society Reviews, 2003
- Toxicological Screening with Formula-Based Metabolite Identification by Liquid Chromatography/Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2003
- Validation of a screening method for corticosteroids in doping analysis by liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2003
- Determination of endogenous and synthetic glucocorticoids in human urine by gas chromatography–mass spectrometry following microwave-assisted derivatizationAnalytica Chimica Acta, 2003
- Screening for 18 diuretics and probenecid in doping analysis by liquid chromatography–tandem mass spectrometryBiomedical Chromatography, 2002
- Determination and characterization of diuretics in human urine by liquid chromatography coupled to pneumatically assisted electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2001