Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study
Open Access
- 20 August 2019
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 20 (1) , 1-7
Abstract
Plate protrusion is a risk factor for flexor pollicis longus (FPL) rupture following volar locking plate (VLP) surgery. However, plate prominence on follow-up radiographs is common. We hypothesised that a VLP that does not touch the FPL tendon can appear as a plate prominence projected over the volar ridge on lateral radiographs. We studied six current designs of widely used plates in formalin-fixed cadavers. Each plate was placed in six cadavers. We analysed 36 different plate–cadaver combinations. The main aim of plate fixation was to position the plate in the most distal position without FPL tendon contact. Radiographs were obtained using fluoroscopy. We evaluated plate prominence from the volar ridge according to the Soong grading system. Soong grades 0 (plate did not extend beyond volar ridge), 1 (plate protruded beyond volar ridge) and 2 (plate directly on or located beyond the volar ridge) were observed in 23 (63.9%), 9 (25.0%) and 4 (11.1%) cadavers, respectively. VariAx, DVR and VALCP showed grade 1 prominence, whereas Acu-Loc2, HYBRIX and MODE showed grade 2 prominence. Implant protrusion was observed in 36% of plate–cadaver combinations, even if the plate did not touch the FPL. Estimating the risk of FPL rupture using lateral radiographs alone is likely insufficient. Our findings can be applied to accurately identify the presence of implant prominence following VLP surgery.Keywords
Funding Information
- Red de Investigación Corporativa Enfermedades Tropicales ((RD12/0018/0008, RD16/0027/0017))
- FEDER
This publication has 23 references indexed in Scilit:
- Tendon Rupture and Tenosynovitis following Internal Fixation of Distal Radius Fractures: A Systematic ReviewPlastic and Reconstructive Surgery, 2017
- The role of post-operative radiographs in predicting risk of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures – A case control studyInjury, 2014
- Volar Plate Fixation for the Treatment of Distal Radius FracturesJournal of Orthopaedic Trauma, 2013
- Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture FixationThe Journal of Hand Surgery, 2013
- Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literatureJournal of Orthopaedics and Traumatology, 2013
- An Anatomical Study of the Watershed Line on the Volar, Distal Aspect of the Radius: Implications for Plate Placement and Avoidance of Tendon RupturesThe Journal of Hand Surgery, 2012
- Volar Locking Plate Implant Prominence and Flexor Tendon RuptureJournal of Bone and Joint Surgery, 2011
- Flexor Pollicis Longus Tendon Ruptures after Palmar Plate Fixation of Fractures of the Distal RadiusJournal of Hand Surgery (European Volume), 2009
- Treatment of Unstable Distal Radial Fractures with the Volar Locking Plating SystemJournal of Bone and Joint Surgery, 2006
- Current Concepts in Volar Fixed-angle Fixation of Unstable Distal Radius FracturesClinical Orthopaedics and Related Research, 2006