Combination of HPLC “Inverted Chirality Columns Approach” and MS/MS Detection for Extreme Enantiomeric Excess Determination Even in Absence of Reference Samples. Application to Camptothecin Derivatives
- 29 June 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (15) , 6013-6019
Abstract
An original, extremely sensitive and selective HPLC−MS/MS technique for the identification and determination of the minor enantiomer in nonracemic mixtures, even when only one enantiomer is available as reference, is described. The method is based on the so-called “inverted chirality columns approach” (ICCA) and consists of the use of chiral stationary phases (CSPs) available in both enantiomeric forms: in fact, inversion of the elution order for a pair of enantiomers is observed in response to the change in column chirality. This offers two key advantages: first, it is possible to demonstrate the potential enantioselectivity of the system by generating a virtual racemate, and second, it permits the choosing of the right column chirality for trace determination. Combination with MS/MS detection affords high specificity allowing not only high sensitivity (down to 0.0025% of the minor enantiomer) but also unequivocal peak identification in complex mixtures. Applications to semisynthetic derivatives of camptothecin, endowed with antitumor activity, are reported. Moreover, applicability of ICCA is not limited to this class of molecules but generates universal support. Its use might also be extended to other classes of compounds by using other CSPs, available in both enantiomeric forms.Keywords
This publication has 13 references indexed in Scilit:
- Chiral SeparationsAnalytical Chemistry, 2006
- Twenty years of research on silica‐based chiral stationary phasesJournal of Separation Science, 2006
- Directly Coupled Chiral HPLC−NMR and HPLC−CD Spectroscopy as Complementary Methods for Structural and Enantiomeric Isomer Identification: Application to Atracurium BesylateAnalytical Chemistry, 1999
- Enantioselective chromatography on brush-type chiral stationary phases containing totally synthetic selectors theoretical aspects and practical applicationsJournal of Chromatography A, 1996
- Accuracy in the chromatographic determination of extreme enantiomeric ratios: A critical reflectionChirality, 1995
- Chromatographic optical resolution on trans‐1,2‐diaminocyclohexane derivatives: Theory and applicationsChirality, 1992
- Chromatographic resolution of 1,2-amino alcohols on a chiral stationary phase containing N,N′-(3,5-dinitrobenzoyl)-trans-1,2-diaminocyclohexaneJournal of Chromatography A, 1991
- Eluting trace components before major constituentsJournal of Chromatography A, 1987
- A unique reversal of elution order during direct enantiomeric resolution of amide derivatives of 1-phenyl-2-aminopropane by high performance liquid chromatography on chiral stationary phasesJournal of High Resolution Chromatography, 1984
- Plant Antitumor Agents. I. The Isolation and Structure of Camptothecin, a Novel Alkaloidal Leukemia and Tumor Inhibitor from Camptotheca acuminata1,2Journal of the American Chemical Society, 1966