Dosimetry on first clinical dark‐field chest radiography
Authors:
Open Access
- 27 July 2021
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (10) , 6152-6159
Abstract
Purpose: The purpose of this study was to evaluate the dose characteristic for patient examinations at the first clinical X‐ray dark‐field chest radiography system and to determine whether the effective patient dose is within a clinically acceptable dose range.Methods: A clinical setup for grating‐based dark‐field chest radiography was constructed and commissioned, operating at a tube voltage of 70 kVp. Thermoluminescent dosimeter (TLD) measurements were conducted using an anthropomorphic phantom modeling the reference person to obtain a conversion coefficient relating dose area product (DAP) to effective patient dose at the dark‐field system. For 92 patients, the DAP values for posterior–anterior measurements were collected at the dark‐field system. Using the previously determined conversion coefficient, the effective dose was calculated.Results: A reference person, modeled by an anthropomorphic phantom, receives an effective dose of 35 µSv. For the examined patients, a mean effective dose of 39 µSv was found.Conclusions: The effective dose at the clinical dark‐field radiography system, generating both attenuation and dark‐field images, is within the range of reported standard dose values for chest radiography.Keywords
Funding Information
- European Research Council (AdG 695045)
- Deutsche Forschungsgemeinschaft (GRK 2274)
This publication has 26 references indexed in Scilit:
- In-vivo dark-field and phase-contrast x-ray imagingScientific Reports, 2013
- Effective Dose Assessment for Participants in the National Lung Screening Trial Undergoing Posteroanterior Chest Radiographic ExaminationsAmerican Journal of Roentgenology, 2013
- Diagnosing and Mapping Pulmonary Emphysema on X-Ray Projection Images: Incremental Value of Grating-Based X-Ray Dark-Field ImagingPLOS ONE, 2013
- Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light sourceProceedings of the National Academy of Sciences, 2012
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- Grating interferometer based scanning setup for hard x-ray phase contrast imagingReview of Scientific Instruments, 2007
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002
- Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area productPhysics in Medicine & Biology, 1992
- ICRP Publication 23International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine, 1985