Precision of the fractionator from Cavalieri designs
- 22 January 2004
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 213 (2) , 205-211
Abstract
Summary: A popular procedure to predict the variance of the fractionator consists in splitting the initial collection of fragments into two subsets, in order to use the corresponding particle counts (or any other pertinent measure), in the calculation. The current formula does not account for local or ‘nugget’ errors inherent in the estimation of fragment contents, however. Moreover, it does not account for the fact that the contribution of the variability between fragments or slices should rapidly decrease as the sampling fraction increases. For these reasons, an update to the formula is overdue. It should be stressed, however, that the formula applies to Cavalieri slices designs – its application for arbitrary partition designs is therefore not warranted.Keywords
This publication has 18 references indexed in Scilit:
- Precision of circular systematic samplingJournal of Microscopy, 2002
- Tissue shrinkage and unbiased stereological estimation of particle number and size*Journal of Microscopy, 2001
- FRACTIONAL TREND OF THE VARIANCE IN CAVALIERI SAMPLINGImage Analysis and Stereology, 2000
- Precision of systematic sampling and transitive methodsJournal of Statistical Planning and Inference, 1999
- Variance prediction under systematic sampling with geometric probesAdvances in Applied Probability, 1998
- Unbiased stereological estimation of the total number of neurons in the subdivisions of the rat hippocampus using the optical fractionatorThe Anatomical Record, 1991
- On the empirical variance of a fractionator estimateJournal of Microscopy, 1990
- Assessment of particle retention and clearance in the intrapulmonary conducting airways of hamster lungs with the fractionator1Journal of Microscopy, 1990
- Stereology of arbitrary particles*Journal of Microscopy, 1986
- The unbiased estimation of number and sizes of arbitrary particles using the disectorJournal of Microscopy, 1984