A matrix effect and accuracy evaluation for the determination of elements in milk powder LIBS and laser ablation/ICP-OES spectrometry
- 15 May 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (9) , 2681-2689
Abstract
Laser ablation coupled to inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and laser-induced breakdown spectroscopy (LIBS) were investigated for the determination of Ca, Mg, Zn and Na in milk samples. The accuracy of both methods was evaluated by comparison of the concentration found using LA-ICP-OES and LIBS with classical wet digestion associated with ICP-OES determination. The results were not fully acceptable, with biases from less than 1% to more than 60%. Matrix effects were also investigated. The sample matrix can influence the temperature, electron number density (n e) and other excitation characteristics in the ICP. These ICP characteristics were studied and evaluated during ablation of eight milk samples. Differences in n e (from 8.9 to 13.8 × 1014 cm−3) and rotational temperature (ranging from 3,400 to 4,400 K) occurred with no correlation with trueness. LIBS results obtained after classical external calibration procedure gave degraded accuracy, indicating a strong matrix effect. The LIBS measurements clearly showed that the major problem in LA-ICP was related to the ablation process and that LIBS spectroscopy is an excellent diagnostic tool for LA-ICP techniques.Keywords
This publication has 28 references indexed in Scilit:
- Comparison of LA-ICP-MS and LA-ICP-OES for the analysis of some elements in fly ashesJournal of Analytical Atomic Spectrometry, 2010
- High-speed digital photographic study of an inductively coupled plasma during laser ablation: comparison of dried solution aerosols from a microconcentric nebulizer and solid particles from laser ablationJournal of Analytical Atomic Spectrometry, 2003
- Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS): Comparison of Different Internal Standardization Methods Using Laser-induced Plasma (LIP) Emission and LA-ICP-MS SignalsAnalytical Sciences, 2002
- Comparison of mass spectrometric and optical measurements of temperature and electron density in the inductively coupled plasma during mass spectrometric samplingSpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Stark-broadened hydrogen line profiles predicted by the model microfield method for calculating electron number densitiesSpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Investigation of matrix effects in inductively coupled plasma-atomic emission spectroscopy using laser ablation and solution nebulization — effect of second ionization potentialSpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Use of magnesium as a test element for inductively coupled plasma atomic emission spectrometry diagnosticsAnalytica Chimica Acta, 1991
- Spectroscopic evaluation of a carbon dioxide and a helium-carbon dioxide microwave-induced plasma (surfatron)Journal of Analytical Atomic Spectrometry, 1988
- An evaluation of ion-atom emission intensity ratios and local thermodynamic equilibrium in an argon inductively coupled plasmaSpectrochimica Acta Part B: Atomic Spectroscopy, 1984
- Electronic excitation and ionization temperature measurements in a high frequency inductively coupled argon plasma source and the influence of water vapour on plasma parametersSpectrochimica Acta Part B: Atomic Spectroscopy, 1980