Effect of preparation design on fracture resistance of molars restored with occlusal veneers of different CAD-CAM materials: an in vitro study
Open Access
- 1 October 2024
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-11
Abstract
Background: Occlusal veneer had been evaluated for mechanical properties using lithium disillicate. However, studies evaluating the mechanical properties of occlusal veneer with different preparation designs and ceramic materials are lacking. So, this in vitro study aimed to evaluate the fracture resistance of occlusal veneers with two designs fabricated from two different ceramic materials. Material and methods: Fourty mandibular third molars were distributed to 2 groups (n = 20) according to preparation design: group (O) anatomical occlusal reduction and group (OA) anatomical occlusal and 1 mm axial reduction. Each group was additionally subdivided into two subgroups (n = 10) according to ceramic materials; in subgroup X, lithium disilicate (e.max CAD, Ivoclar AG, Schaan, Liechtenstein) was used, and in subgroup S, zirconia-reinforced lithium silicate (ZLS) (Vita Suprinity, VitaZahnfabrik, Bad Säckingen, Germany) was used. All specimens were cemented with a light-cure resin cement (Choice 2, Bisco, Schaumburg, USA). 5000 thermocycles were applied to all specimens with both temperatures of 5 °C and 55 °C in two water baths; the dwell time was 30s at each bath, and the transfer time was 10s. Then all specimens were subjected to a fatigue simulation under dynamic loading of 200 N for 250,000 cycles. A universal testing machine (5500R/1123, Instron, Norwood, USA) was used to evaluate the fracture strength with a crosshead speed of 1 mm/min. All data were analyzed statistically by using a two-way ANOVA, and for some violations of assumptions, these results were compared with those obtained by the nonparametric test (Scheirer Ray Hare) (α = 0.05). Results: A statistically significantly higher fracture resistance in the ‘OA’ (3389 N) compared to the ‘O’ (2787 N) group regardless of the ceramic material (P < .001) and a statistically significantly higher fracture resistance in the ‘X’ (3295 N) compared to the ‘S’ (2881 N) regardless of the preparation design (P = .015). Conclusions: For occlusal veneers, all preparation designs and materials (such as Vita Suprinity and e.max CAD) had clinically acceptable fracture resistance values that were greater than the maximal biting forces. On the other hand, the e.max CAD with occlusal veneer, including axial reduction design, demonstrated the maximum fracture resistance value. Finally, no relationship between fracture strength and mode of failure was found.Keywords
Funding Information
- Kafr El Shiekh University
This publication has 56 references indexed in Scilit:
- Modeling of ultrathin occlusal veneersDental Materials, 2012
- Restoration of noncarious tooth defects by dentists in The Dental Practice-Based Research NetworkThe Journal of the American Dental Association, 2011
- Composite vertical bite reconstructions in eroded dentitions after 5·5 years: a case seriesJournal of Oral Rehabilitation, 2011
- In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneersThe Journal of Prosthetic Dentistry, 2010
- A prospective 15-year evaluation of extensive dentin–enamel-bonded pressed ceramic coveragesDental Materials, 2010
- A Conservative Approach for Treating Young Adult Patients with Porcelain Laminate VeneersJournal of Esthetic and Restorative Dentistry, 2008
- Minimal preparation designs for single posterior indirect prostheses with the use of the Cerec system.2008
- Failure analysis of ceramic clinical cases using qualitative fractography.2006
- In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth.2001
- The effect of variations in bonding procedure on fracture resistance of dentin-bonded all-ceramic crowns.1995