Abstract
Background: Laparoscopic intragastric surgery (LIGS) requires a “pneumostomach,” which is created by air insufflation via gastroscopy. If the procedure is done without duodenal clamping, migrated air from the stomach causes excessive, prolonged bowel distention, which may lead to drawbacks during and after the operation. Carbon dioxide (CO2), with its faster absorption than air, can attenuate bowel distention when used to establish the pneumostomach. The aims of this study were to evaluate feasibility, safety, and effectiveness of the CO2 pneumostomach in LIGS. Methods: We have performed 15 LIGSs under the CO2 pneumostomach (January 1997 to August 2004). The stomach was insufflated with CO2 through an automatic surgical insufflator up to 8 mm Hg of intraluminal pressure. Neither a duodenal clamp nor an occlusion was employed prior to insufflation. Cardiopulmonary parameters were prospectively registered and retrospectively analyzed. The degree and extent of bowel distention was assessed by a concluding laparoscopy, and the amount of intestinal gas was evaluated by a postoperative plain abdominal radiograph. Results: LIGS was completed in all 15 cases, with a mean intragastric insufflation time of 100 minutes. The CO2 pneumostomach provided good, constant surgical exposure with sufficient working space. No adverse impact of intragastric CO2 insufflation was observed on the cardiopulmonary function. Even without duodenal clamping, the insufflated small bowel loops already shrank at the time of the concluding laparoscopy. Fair residual gas was documented radiologically in 2 cases, whereas it was only faint in the remaining 13 cases. No patients showed abdominal pain or bloating postoperatively. Conclusions: The CO2 pneumostomach is a feasible, safe alternative and is potentially effective for LIGS by eliminating the need for prior duodenal clamping and by minimizing bowel distention.Keywords
This publication has 15 references indexed in Scilit:
- A versatile dual-channel carbon dioxide (CO2) insufflator for various CO2 applicationsSurgical Endoscopy, 2005
- Intraoperative carbon dioxide colonoscopy: a safe insufflation alternative for locating colonic lesions during laparoscopic surgerySurgical Endoscopy, 2005
- Randomized, Controlled Trial of Carbon Dioxide Insufflation During ColonoscopyDiseases of the Colon & Rectum, 2003
- Endoscopy during laparoscopySurgical Endoscopy, 1999
- Laparoscopic intraluminal (intragastric) surgery for early gastric cancerSurgical Endoscopy, 1995
- Pain following colonoscopy: elimination with carbon dioxideGastrointestinal Endoscopy, 1992
- Who's for CO2?Gastrointestinal Endoscopy, 1986
- Carbon dioxide-insufflated colonoscopy: an ignored superior techniqueGastrointestinal Endoscopy, 1986
- Carbon dioxide insufflation for more comfortable colonoscopyGastrointestinal Endoscopy, 1984
- INTESTINAL RESPONSE TO CHANGING GASEOUS ENVIRONMENTS: NORMOBARIC AND HYPERBARIC OBSERVATIONS*Annals of the New York Academy of Sciences, 1968