Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients
Open Access
- 12 December 2006
- journal article
- clinical trial
- Published by Springer Nature in Critical Care
- Vol. 10 (6) , R171
Abstract
Background: Left ventricular stroke area by transoesophageal echocardiographic automated border detection has been shown to be strongly correlated to left ventricular stroke volume. Respiratory variations in left ventricular stroke volume or its surrogates are good predictors of fluid responsiveness in mechanically ventilated patients. We hypothesised that respiratory variations in left ventricular stroke area (ΔSA) can predict fluid responsiveness. Methods: Eighteen mechanically ventilated patients undergoing coronary artery bypass grafting were studied immediately after induction of anaesthesia. Stroke area was measured on a beat-to-beat basis using transoesophageal echocardiographic automated border detection. Haemodynamic and echocardiographic data were measured at baseline and after volume expansion induced by a passive leg raising manoeuvre. Responders to passive leg raising manoeuvre were defined as patients presenting a more than 15% increase in cardiac output. Results: Cardiac output increased significantly in response to volume expansion induced by passive leg raising (from 2.16 ± 0.79 litres per minute to 2.78 ± 1.08 litres per minute; p < 0.01). ΔSA decreased significantly in response to volume expansion (from 17% ± 7% to 8% ± 6%; p < 0.01). ΔSA was higher in responders than in non-responders (20% ± 5% versus 10% ± 5%; p < 0.01). A cutoff ΔSA value of 16% allowed fluid responsiveness prediction with a sensitivity of 92% and a specificity of 83%. ΔSA at baseline was related to the percentage increase in cardiac output in response to volume expansion (r = 0.53, p < 0.01). Conclusion: ΔSA by transoesophageal echocardiographic automated border detection is sensitive to changes in preload, can predict fluid responsiveness, and can quantify the effects of volume expansion on cardiac output. It has potential clinical applications.Keywords
This publication has 49 references indexed in Scilit:
- Echocardiographic measurement of fluid responsivenessCurrent Opinion in Critical Care, 2006
- The Influence of Tidal Volume on the Dynamic Variables of Fluid Responsiveness in Critically Ill PatientsAnesthesia & Analgesia, 2006
- ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary ArticleCirculation, 2003
- Left ventricular pressure-volume relations with transesophageal echocardiographic automated border detection: Comparison with conductance-catheter techniqueAmerican Heart Journal, 1996
- On-line estimation of changes in left ventricular stroke volume by transesophageal echpcardiographic automated border detection in patients undergoing coronary artery bypass graftingThe American Journal of Cardiology, 1993
- On-line estimation of stroke volume by means of echocardiographic automated border detection in the canine left ventricleAmerican Heart Journal, 1993
- Accuracy of volume determination by two-dimensional echocardiography: defining requirements under controlled conditions in the ejecting canine left ventricle.Circulation, 1983
- Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man.Circulation, 1981
- Accurate volume determination in the isolated ejecting canine left ventricle by two-dimensional echocardiography.Circulation, 1979
- Effect of phasic respiration on left ventricular dimension and performance in a normal population. An echocardiographic study.Circulation, 1978