Abstract
The article presents the characteristics of several steel structures, among others modernized industrial dye house, school sports hall, truck repair workshop, that have been rebuilt after a disaster or a catastrophe. The structures were analyzed in detail, and the evaluation and reconstruction processes were described. The emergencies that occurred during exploitation of the buildings were the result of multiple mistakes: incorrectly defined intervals between inspections, errors during periodic inspections, incorrect repair work recommendations. The concepts of reinforcement work implemented by the authors, enabling the long-term future failure-free operation of the objects, were presented. Recommendations for monitoring of the facilities, applied after reinforcement or reconstruction, have been formulated. The methodology for the implementation of specialized investigations, such as geodetic, optical, geological, chemical strength tests, both destructive and non-destructive, has been defined. The need to determine the limit values of deformations, deflections, damage or other faults of structural elements and the entire rebuilt facilities, as well as defining conditions for objects' withdrawal from operation in subsequent exceptional situations was indicated.Keywords
This publication has 10 references indexed in Scilit:
- Lateral buckling failure of steel cantilever roof of a tribune due to snow loadsEngineering Failure Analysis, 2017
- Local buckling behavior of welded stub columns with normal and high strength steelsJournal of Constructional Steel Research, 2016
- Numerical investigation of the lateral–torsional buckling of beams with slender cross sections for the case of fireEngineering Structures, 2016
- Lateral buckling of box beam elements under combined axial and bending loadsJournal of Constructional Steel Research, 2016
- Disaster of an industrial hall caused by an explosion of wood dust and fireEngineering Failure Analysis, 2015
- Steel roofing disaster and the effect of the failure of butt jointsEngineering Failure Analysis, 2014
- Failure analysis of a collapsed flat gymnasium roofEngineering Failure Analysis, 2013
- Buckling Analysis of a Long-Span Roof Structure Collapsed during ConstructionJournal of Performance of Constructed Facilities, 2013
- Buckling failure of an unusual braced steel frame supporting an electric dust-catcherEngineering Failure Analysis, 2009
- Collapse of Katowice Fair BuildingEngineering Failure Analysis, 2009