Improving serotonin fast-scan cyclic voltammetry detection: new waveforms to reduce electrode fouling
- 9 November 2020
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (22) , 7437-7446
Abstract
Serotonin is a neuromodulator implicated in depression that is often measured in real-time by fast-scan cyclic voltammetry (FSCV). A specialized “Jackson” waveform (JW, 0.2, 1.0 V, −0.1 V, 0.2 V, 1000 V s−1) was developed to reduce serotonin fouling, but the 1.0 V switching potential limits sensitivity and electrodes still foul. The goal of this study was to test the effects of extending the FSCV switching potential to increase serotonin sensitivity and decrease fouling. We compared the Jackson waveform, the dopamine waveform (DA, −0.4 V, 1.3 V, 400 V s−1), and two new waveforms: the extended serotonin waveform (ESW, 0.2, 1.3, −0.1, 0.2, 1000 V s−1) and extended hold serotonin waveform (EHSW, 0.2, 1.3 (hold 1 ms), −0.1, 0.2, 400 V s−1). The EHSW was the most sensitive (LOD = 0.6 nM), and the JW the least sensitive (LOD = 2.4 nM). With the Jackson waveform, electrode fouling was significant with repeated injections of serotonin or exposure to its metabolite, 5-hydroxyindoleacetic acid (5-HIAA). Using the extended waveforms, electrodes fouled 50% less than with the Jackson waveform for both analytes. No electrode fouling was observed with the dopamine waveform because of the negative holding potential. The Jackson waveform was the most selective for serotonin over dopamine (800×), and the ESW was also highly selective. All waveforms were useful for measuring serotonin with optogenetic stimulation in Drosophila larvae. These results provide new FSCV waveforms to measure dynamic serotonin changes with different experimental requirements, like high sensitivity (EHSW), high selectivity (ESW, JW), or eliminating electrode fouling (DA).Keywords
Funding Information
- National Institutes of Health (R01MH085159)
This publication has 39 references indexed in Scilit:
- In vivoelectrochemical evidence for simultaneous 5‐HT and histamine release in the rat substantia nigra pars reticulata following medial forebrain bundle stimulationJournal of Neurochemistry, 2011
- Higher Sensitivity Dopamine Measurements with Faster-Scan Cyclic VoltammetryAnalytical Chemistry, 2011
- Both synthesis and reuptake are critical for replenishing the releasable serotonin pool in DrosophilaJournal of Neurochemistry, 2010
- Carbon Microelectrodes with a Renewable SurfaceAnalytical Chemistry, 2010
- Voltammetric Detection of 5-Hydroxytryptamine Release in the Rat BrainAnalytical Chemistry, 2009
- Quantitative evaluation of serotonin release and clearance in DrosophilaJournal of Neuroscience Methods, 2009
- Carbon-fiber microelectrodes for in vivo applicationsThe Analyst, 2008
- Advanced Carbon Electrode Materials for Molecular ElectrochemistryChemical Reviews, 2008
- Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivityElectronic supplementary information (ESI) available: National Instruments Data Acquisition System. See http://www.rsc.org/suppdata/an/b3/b307024g/The Analyst, 2003
- Mechanism and products of electrochemical oxidation of 5,7-dihydroxy trytamineJournal of the American Chemical Society, 1989