Relationship Among Corneal Stiffness, Thickness, and Biomechanical Parameters Measured by Corvis ST, Pentacam and ORA in Keratoconus
Authors:
Open Access
- 13 June 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 740
Abstract
Purpose: To assess the relationship among corneal stiffness, thickness, and biomechanical parameters in keratoconus. Setting: The EENT Hospital of Fudan University, Shanghai, China. Design: Comparative study. Methods: In this cross-sectional prospective study, 75 keratoconic eyes of 44 patients were recruited. Eyes were divided three groups according to the steepest K-readings (Kmax): mild (31 eyes; 42.1–54.5D); moderate (27 eyes, 55.0–61.6D); and severe (17 eyes, 65.2–94.5D). Thirty-one healthy subjects were recruited as the control group. All patients underwent Corvis ST, Pentacam and ORA examinations at the same time. Stiffness parameter A1 (SP-A1) and other dynamic parameters were assessed using the Corvis ST. Kmax and thinnest corneal thickness (TCT) was obtained using the Pentacam. Corneal resistance factor (CRF) and corneal hysteresis (CH) were measured using the ORA. Analysis of correlation was applied to investigate the association between variables. Results: There was a decrease in SP-A1 in different stages of keratoconus compared with controls (P ≤ 0.001): with increasing severity, the value of SP-A1 became smaller (P < 0.05). A statistically significant linear relationship was noted between SP-A1 and TCT in each subgroup of keratoconus (P ≤ 0.001). In all three groups, SP-A1 was found to be positively correlated with first applanation time (P < 0.01), while negatively correlated with deformation amplitude (P < 0.05). Analysis of SP-A1 with regard to CRF and CH indicated statistically positive correlation in keratoconus (P < 0.05). Conclusion: Significant decreases in corneal stiffness were noted in kerotoconic eyes compared with normal eyes. The stiffness parameter could be a valuable clinical tool enables biomechanically track progression with keratoconus. Synopsis: Our study found that corneal thinning and biomechanical decreasing synchronize with one another throughout the progression of the keratoconus, and SP-A1 could be a potential biomarker evaluating disease progression.Keywords
This publication has 25 references indexed in Scilit:
- Global Consensus on Keratoconus and Ectatic DiseasesCornea, 2015
- Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based TonometerInvestigative Ophthalmology & Visual Science, 2014
- Improved Keratoconus Detection by Ocular Response Analyzer Testing After Consideration of Corneal Thickness as a Confounding FactorJournal of Refractive Surgery, 2012
- Ocular Response Analyzer Measurements in Keratoconus with Normal Central Corneal Thickness Compared with Matched Normal Control EyesJournal of Refractive Surgery, 2011
- Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild KeratoconusOphthalmology, 2010
- Hysteresis: New mechanospeak for the ophthalmologistJournal of Cataract & Refractive Surgery, 2007
- Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconusJournal of Cataract & Refractive Surgery, 2006
- Comparative study of corneal strip extensometry and inflation testsJournal of The Royal Society Interface, 2005
- Keratoconus and related noninflammatory corneal thinning disordersSurvey of Ophthalmology, 1984
- Biomechanical properties of keratoconus and normal corneasExperimental Eye Research, 1980