Activation, Decay Heat, and Waste Disposal Analyses for the ARIES-AT Power Plant
Authors:
- P. WilsonPWP. Wilson
- A. AbdouA. Abdou
- Aries TeamATAries Team
- 1 March 2001
- journal article
- research article
- Published by American Nuclear Society in Fusion Technology
- Vol. 39 (2P2) , 444-448
Abstract
Detailed activation, decay heat and waste disposal calculations of the ARIES-AT design are performed to evaluate the safety aspects of the device. The high initial activity of the SiC highly irradiated components translates directly into a higher initial decay heat for these structures than for the well-protected steel-based components. However, after a one-hour cool-down period, the SiC decay heat drops by two decades to levels comparable to the steel-based components. The decay heat of the LiPb coolant was found to exceed that of the SiC components for several days after shutdown. This implies that a loss of flow accident (LOFA) event is more critical than a loss of coolant accident (LOCA) event for LiPb/SiC systems. Regarding waste disposal, all structures can easily meet the Class C Low-Level Waste (LLW) requirements established for the ARIES power plants. Many components could qualify as Class A LLW after a 100-year storage period after selection of low activation materials and control of the Nb and Mo impurities in ferritic steel. A purification system will be required to remove the 210Po and 203Hg generated by Pb during operation.Keywords
This publication has 1 reference indexed in Scilit:
- Long-term radioactive waste from fusion reactors: Part IIFusion Engineering and Design, 1990