Mass spectrometry is widely applied in carbohydrate analysis, but still quantitative evaluation of data is critical due to different ionization efficiencies of the constituents in a mixture. Different size and chemical structure of the analytes cause their uneven distribution in droplets (electrospray ionization, ESI) or matrix spots (matrix‐assisted laser desorption/ionization, MALDI). In addition, instrumental parameters affect final ion yields. In order to study and optimize the latter, an equimolar mixture of malto‐oligosaccharides (DP1‐6) was analyzed using varying target masses for ESI as well as different matrices and laser power for MALDI. The sodium adducts and derivatives for positive ion mode (hydrazones with Girard's T Reagent, GT) and negative ion mode (reductively aminated with o ‐aminobenzoic acid, oABA) were studied. Negatively charged oABA‐labeled malto‐oligosaccharides turned out to be unsuitable for quantification of the malto‐oligomeric composition. Best agreement was achieved when applying target masses in the range of the highest homolog in the mixture in electrospray ionization ion trap (ESI‐IT) (1–2% deviation with GT label or as Na + adducts). Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) gave best results when the laser power was adjusted significantly over the desorption/ionization threshold (1% deviation with GT label). Both parameters show significant influence on the determined oligomeric composition. Consequently, estimation and even quantitative determination of amounts of oligosaccharides in a mixture can be achieved when the analytes are labeled and the proper instrumental parameters are used. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 41 references indexed in Scilit:
- Fractionation of Methyl Cellulose According to Polarity – a Tool to Differentiate First and Second Order Heterogeneity of the Substituent DistributionMacromolecular Chemistry and Physics, 2006
- New Approaches to the Analysis of Enzymatically Hydrolyzed Methyl Cellulose. Part 2. Comparison of Various Enzyme PreparationsBiomacromolecules, 2006
- Analysis of the substituent distribution in the glucosyl units and along the polymer chain of hydroxypropylmethyl celluloses and statistical evaluationCellulose, 2006
- Comprehensive Analysis of the Substituent Distribution in the Glucosyl Units and along the Polymer Chain of Hydroxyethylmethyl Celluloses and Statistical EvaluationAnalytical Chemistry, 2006
- Improved Chemical Analysis of Cellulose Ethers Using Dialkylamine Derivatization and Mass SpectrometryBiomacromolecules, 2005
- Recent Advances in MALDI Mass Spectrometry of PolymersMacromolecular Symposia, 2004
- Analytical Approaches to Improved Characterization of Substitution in Hydroxypropyl CelluloseAnalytical Chemistry, 2003
- New results on matrix‐assisted laser desorption/ionization mass spectrometry of widely polydisperse hydrosoluble polymersRapid Communications in Mass Spectrometry, 2002
- Why Does Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry Give Incorrect Results for Broad Polymer Distributions?Rapid Communications in Mass Spectrometry, 1996
- Quantitative bioanalysis using matrix‐assisted laser desorption/ionization mass spectrometryJournal of Mass Spectrometry, 1995