Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs
Open Access
- 1 July 2016
- journal article
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 30 (4) , 983-988
Abstract
Background: A novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. Objectives: To assess the clinical and analytical accuracy of the FGMS in diabetic dogs. Animals: Ten client-owned diabetic dogs on insulin treatment. Methods: Prospective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st–2nd, 6–7th, and 13–14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. Results: The application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean ± standard deviation difference from the reference method was 2.3 ± 46.8 mg/dL. Conclusion and clinical importance: The FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.Keywords
This publication has 17 references indexed in Scilit:
- The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2015
- CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose MonitoringJournal of Diabetes Science and Technology, 2015
- ISO-Based Assessment of Accuracy and Precision of Glucose Meters in DogsJournal of Veterinary Internal Medicine, 2014
- Continuous Glucose Monitoring in the Subcutaneous Tissue over a 14-Day Sensor Wear PeriodJournal of Diabetes Science and Technology, 2013
- Comparison of Glucose Fluctuations between Day- and Night-Time Measured Using a Continuous Glucose Monitoring System in Diabetic DogsJournal of Veterinary Medical Science, 2013
- Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient dataBMJ, 2011
- A pilot study to evaluate a novel subcutaneous continuous glucose monitoring system in healthy Beagle dogsThe Veterinary Journal, 2010
- Continuous Glucose Monitoring in Dogs and CatsJournal of Veterinary Internal Medicine, 2008
- Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring SystemDiabetes Care, 2007
- Evaluation of a Continuous Glucose Monitoring System for Use in Veterinary MedicineDiabetes Technology & Therapeutics, 2005