The Effect of Noise When Deriving Signals from Accelerometers
Authors:
- 1 February 1982
- journal article
- research article
- Published by SAGE Publications in Measurement and Control
- Vol. 15 (2) , 59-61
Abstract
The effect of noise is often ignored when accelerometer signals are integrated to give velocity and displacement. The main forms of noise to be found in a system which operates in this way are identified, and analysis shows the interdependence of the magnitude of the noise, the system bandwidth and the signal-to-noise ratio of the final displacement output. It is shown that the signal-to-noise ratio is degraded significantly by the integration process; thus noise introduced before integration, by signal amplification, recording, or other conditioning is critical.Keywords
This publication has 4 references indexed in Scilit:
- An instrument for the measurement of structural vibrationsThe Journal of Strain Analysis for Engineering Design, 1979
- The sensitivity and dynamic range of inertial seismographsReviews of Geophysics, 1976
- Developments in seismometryJournal of Physics E: Scientific Instruments, 1973
- "Pixie" cardiography. Accelerometer applications to phonocardiography and displacement cardiography in childhood.Heart, 1971