Bearing strength of carbon fibre/epoxy laminate with direct measurement of hole deformation
- 16 July 2013
- journal article
- research article
- Published by Taylor & Francis in Advanced Composite Materials
- Vol. 22 (5) , 311-325
Abstract
The bearing strength of carbon fibre/epoxy laminates composite has been investigated with a new failure criteria instead of conventional load. A precise measurement of hole deformation allows to determine the failure load as a clear kink point on the load-displacement curve. The validity of the new failure criteria was evaluated by cyclic load tests. With the new failure criteria, the effect of bolt-hole clearance and the clamping force were re-evaluated. Effect of the gap between the specimen and bush was also investigated. The experiments show more than 0.1 mm clearance for 6.35-mm hole affect for the failure load but not maximum load. The tightening up torque affects both the failure and maximum load up to . The gap between specimen and bush strongly affect the maximum load but not failure load. These results give a design criteria for thickness tolerance for the cases of using collar on the hole. Significant deviation between conventional load and new failure load were found in several conditions.Keywords
This publication has 18 references indexed in Scilit:
- A New Concept for Structural Health Monitoring of Bolted Composite JointsKey Engineering Materials, 2007
- Effect of washer size and tightening torque on the performance of bolted joints in composite structuresComposite Structures, 2006
- Bearing strength of carbon fibre/epoxy laminates: effects of bolt-hole clearanceComposites Part B: Engineering, 2004
- Effects of stacking sequence and clamping force on the bearing strengths of mechanically fastened joints in composite laminatesComposite Structures, 2001
- Modelling Clamp-Up Effects in Composite Bolted JointsJournal of Composite Materials, 1987
- The Effects of Pin Elasticity, Clearance, and Friction on the Stresses in a Pin-Loaded Orthotropic PlateJournal of Composite Materials, 1987
- Contact stresses in bolted joints of composite laminatesComposite Structures, 1986
- On the bearing strengths of cfrp laminatesComposites, 1982
- The strength of bolted joints in multi-directional cfrp laminatesComposites, 1977
- The effect of clamping pressure on bolt bearing loads in glass fibre-reinforced plasticsComposites, 1976