Evolving the Medipix2 Technology For Use As An Active Space Radiation Dosimeter
- 1 March 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2008 IEEE Aerospace Conference
- No. 1095323X,p. 1-8
Abstract
As reported last year, a new solid state detector, known as Medipix, developed by a consortium of academic institutions has been evolved from a technology originally created for use at the LHC at CERN in Geneva, Switzerland. This technology is being harnessed for use as an active personal dosimeter for space radiation applications. The pixel based technology embeds the entire required readout electronics for each pixel within the pixel's 55 micron square footprint. That allows the seamless tiling of multiple arrays of detectors. Ultimate versions may be deployed that are both wireless and self-contained, as well as having a package size comparable to current passive personal dosimeters. Prospect are excellent for building them into spacesuits, which would provide ground-based real-time monitoring of the detailed doses being taken by crew members during such high-risk periods as EVAs. These dosimeters could also be used as active area monitors in a variety of both space and ground-based applications. An advanced version of this technology, known as TimePix, that effectively incorporates a pixel-by-pixel Analog to Digital Conversion (ADC) capability has recently become available, and we anticipate that a report of initial accelerator tests of the capability of this version will be reported at the conference, although those results are not available at the time of the submission of this paper.Keywords
This publication has 4 references indexed in Scilit:
- Study of the charge sharing in a silicon pixel detector by means of α-particles interacting with a Medipix2 deviceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Pattern recognition of tracks induced by individual quanta of ionizing radiation in Medipix2 silicon detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- USB interface for Medipix2 pixel device enabling energy and position-sensitive detection of heavy charged particlesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting modeIEEE Transactions on Nuclear Science, 2002