Advancing AMD screening with an offline, AI-powered smartphone-based fundus camera: A prospective, real-world clinical validation
- 11 July 2025
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 39 (13) , 2548-2554
Abstract
Objectives This study evaluated a novel offline, AI-driven age-related macular degeneration (AMD) screening algorithm against fundus image-only grading and the standard of care (combined Spectral Domain-Optical Coherence Tomography (SD-OCT) and fundus image grading). Methods Conducted prospectively at a South Asian tertiary eye hospital, this study utilized a validated smartphone-based non-mydriatic fundus camera to capture macula-centred images. The Medios AI’s ability to detect referable AMD was compared to a reference standard image grading, using fundus images from the Zeiss Clarus 700 table-top camera and SD-OCT line scan across fovea. Three retina specialists provided blinded AMD diagnoses based on: (1) Zeiss Clarus 700 fundus images alone, and (2) combined SD-OCT and fundus images (standard of care). Referable AMD was defined as intermediate or advanced AMD. Results Among 984 eyes from 492 patients (mean age 61.8 ± 9.9 years), 52% had referable AMD. Inter-grader agreement was strong, with Cohen’s Kappa scores of 0.81–0.84. The Medios AI’s sensitivity and specificity for detecting referable AMD against fundus-only grading (n = 492) were 88.48% (95% CI: 84.04–92.03%) and 87% (95% CI: 81.86–91.11%), respectively. Against combined grading (n = 489), AI sensitivity was 90.62% (95% CI: 86.37–93.90%), and specificity was 85.41% (95% CI: 80.21–89.68%). False negatives were primarily intermediate AMD (71%), while 59% of false positives were early AMD. Conclusion The novel, automated, offline AMD AI integrated on a smartphone fundus camera demonstrated robust performance in identifying referable forms of AMD, supporting its potential as an affordable and accessible screening solution.Keywords
This publication has 39 references indexed in Scilit:
- Retina Fundus Photograph-Based Artificial Intelligence Algorithms in Medicine: A Systematic ReviewOphthalmology and Therapy, 2024
- Artificial intelligence for the detection of age-related macular degeneration in color fundus photographs: A systematic review and meta-analysiseClinicalMedicine, 2021
- Diagnostic Accuracy of Community-Based Diabetic Retinopathy Screening With an Offline Artificial Intelligence System on a SmartphoneJAMA Ophthalmology, 2019
- Development and Validation of a Deep Learning System for Diabetic Retinopathy and Related Eye Diseases Using Retinal Images From Multiethnic Populations With DiabetesJAMA, 2017
- Automated Grading of Age-Related Macular Degeneration From Color Fundus Images Using Deep Convolutional Neural NetworksJAMA Ophthalmology, 2017
- Cost-Effectiveness of Screening for Intermediate Age-Related Macular Degeneration during Diabetic Retinopathy ScreeningOphthalmology, 2015
- Risk Factors for Four-Year Incidence and Progression of Age-Related Macular Degeneration: The Los Angeles Latino Eye StudyAmerican Journal of Ophthalmology, 2011
- The Natural History and Prognosis of Neovascular Age-Related Macular DegenerationOphthalmology, 2008
- A Simplified Severity Scale for Age-Related Macular DegenerationArchives of Ophthalmology (1950), 2005
- A Randomized, Placebo-Controlled, Clinical Trial of High-Dose Supplementation With Vitamins C and E, Beta Carotene, and Zinc for Age-Related Macular Degeneration and Vision LossArchives of Ophthalmology (1950), 2001