Imaging Modalities for Localization of an iStent ®
Authors:
- L. Jay KatzLKL. Jay Katz
- Rick GilleRGRick Gille
- Elizabeth AffelEAElizabeth Affel
- 1 November 2010
- journal article
- research article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 41 (6) , 660-663
Abstract
The iStent (Glaukos Corporation, Laguna Hills, CA) is a 1-mm, titanium trabecular bypass stent implanted across the inner wall of Schlemm’s canal under direct gonioscopy. This study was designed to determine the best modality to identify iStent placement when gonioscopic visualization is not possible. In this in vitro study on a human cadaver eye, ultrasound biomicroscopy (UBM), anterior segment optical coherence tomography (AS-OCT), and B-scan ultrasonography were done to visualize and precisely locate two intentionally misplaced iStents. UBM could localize both intentionally misplaced stents, whereas AS-OCT could not visualize the iStent that was lodged in the sulcus. B-scan ultrasonography was unable to detect either of the stents. UBM may be a useful imaging modality to identify iStent in the anterior or posterior chamber, whereas AS-OCT is limited to detection of stents in the anterior chamber alone. B-scan ultrasonography is unable to identify iStent in either the anterior or posterior chamber.Keywords
This publication has 14 references indexed in Scilit:
- Fluorophotometric Study of the Effect of the Glaukos Trabecular Microbypass Stent on Aqueous Humor DynamicsInvestigative Ophthalmology & Visual Science, 2010
- Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucomaJournal of Cataract & Refractive Surgery, 2010
- Use of novel devices for control of intraocular pressureExperimental Eye Research, 2009
- Glaukos iStent® trabecular micro-bypassMiddle East African Journal of Ophthalmology, 2009
- Coexistent primary open-angle glaucoma and cataract: Preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stentAdvances in Therapy, 2008
- Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomographyCurrent Opinion in Ophthalmology, 2008
- Initial clinical experience with the trabecular micro-bypass stent in patients with glaucomaAdvances in Therapy, 2007
- Comparison of Optical Coherence Tomography and Ultrasound Biomicroscopy for Detection of Narrow Anterior Chamber AnglesArchives of Ophthalmology (1950), 2005
- Real-Time Optical Coherence Tomography of the Anterior Segment at 1310 nmArchives of Ophthalmology (1950), 2001
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994