Analysis of Mtwo Rotary Instrument Separation During Endodontic Therapy: A Retrospective Clinical Study
- 8 May 2014
- journal article
- Published by Springer Nature in Cell Biochemistry and Biophysics
- Vol. 70 (2) , 1091-1095
Abstract
To analyze the incidence of instrument separation (IS) and the factors influencing it, when associated with Mtwo rotary system (VDW, Munich, Germany) during endodontic therapy. A retrospective study involving a total of 24,108 root canals (11,036 endodontic treated teeth) was conducted at Nanjing Stomatology Hospital between January 2011 and March 2013. The information included were tooth type, root canal curvature, number of fractured instruments, length of the separated fragments, and the distance from broken tip to apex. The incidence of IS was observed to be 2.2 % according to the number of teeth and 1.0 % according to the number of root canals. Many of the separated fragments were 2-4 mm in length and the mean length was 3.07 ± 1.46 mm, and 78.4 % of fractures occurred in the apex. The mean length of separated fragments in severely curved canals was maximum, while ultra-severe curved canals was observed to be minimum. Mtwo instruments demonstrated an extremely low fracture rate during endodontic therapy. Molar teeth (especially lower molars) and the degree of canal curvature had a significant effect on the incidence of IS.Keywords
This publication has 25 references indexed in Scilit:
- Assessment of the Separation Incidence of Mtwo Files Used with Preflaring: Prospective Clinical StudyJournal of Endodontics, 2012
- Cyclic Fatigue of Nickel-Titanium Rotary Instruments in a Double (S-shaped) Simulated CurvatureJournal of Endodontics, 2012
- Effect from Cyclic Fatigue of Nickel-Titanium Rotary Files on Torsional ResistanceJournal of Endodontics, 2012
- Instrument Separation Analysis of Multi-used ProTaper Universal Rotary System during Root Canal TherapyJournal of Endodontics, 2011
- Deformation and Fracture of Mtwo Rotary Nickel-Titanium Instruments After Clinical UseJournal of Endodontics, 2009
- Root canal preparation with the NiTi systems K3, Mtwo and ProTaperAustralian Endodontic Journal, 2007
- Comparison of Defects in ProFile and ProTaper Systems after Clinical UseJournal of Endodontics, 2006
- Defects in Rotary Nickel-Titanium Files After Clinical UseJournal of Endodontics, 2000
- A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instrumentsJournal of Endodontics, 1995
- An initial investigation of the bending and torsional properties of nitinol root canal filesJournal of Endodontics, 1988