Secondary electron time detector for mass measurements at CSRe

Authors:
  • TXTu Xiao-Lin
    Tu Xiao-Lin
  • WMWang Meng
    Wang Meng
  • HZHu Zheng-Guo
    Hu Zheng-Guo
  • XHXu Hu-Shan
    Xu Hu-Shan
  • GZGuo Zhong-Yan
    Guo Zhong-Yan
  • MRMao Rui-Shi
    Mao Rui-Shi
  • XGXiao Guo-Qing
    Xiao Guo-Qing
  • ZHZhang Hong-Bin
    Zhang Hong-Bin
  • ZYZang Yong-Dong
    Zang Yong-Dong
  • YKYue Ke
    Yue Ke

Abstract
The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deffected 180° by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10-6 for m/m was achieved by using this time detector in a pilot mass measurement experiment.

This publication has 8 references indexed in Scilit: