Spectral Simulation Methodology for Calibration Transfer of Near-Infrared Spectra
Authors:
- 1 April 2007
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 61 (4) , 406-413
Abstract
A spectrum simulation method is described for use in the development and transfer of multivariate calibration models from near-infrared spectra. By use of previously measured molar absorptivities and solvent displacement factors, synthetic calibration spectra are computed using only background spectra collected with the spectrometer for which a calibration model is desired. The resulting synthetic calibration set is used with partial least squares regression to form the calibration model. This methodology is demonstrated for use in the analysis of physiological levels of glucose (1–30 mM) in an aqueous matrix containing variable levels of alanine, ascorbate, lactate, urea, and triacetin. Experimentally measured data from two different Fourier transform spectrometers with different noise levels and stabilities are used to evaluate the simulation method. With the more stable instrument (A), well-performing calibration models are obtained, producing a standard error of prediction (SEP) of 0.70 mM. With the less stable instrument (B), the calibration based solely on synthetic spectra is less successful, producing an SEP value of 1.58 mM. For cases in which the synthetic spectra do not describe enough spectral variance, an augmentation protocol is evaluated in which the synthetic calibration spectra are augmented with the spectra of a small number of experimentally measured calibration samples. For instruments A and B, respectively, augmentation with measured spectra of nine samples lowers the SEP values to 0.64 and 0.85 mM.Keywords
This publication has 25 references indexed in Scilit:
- Evaluation of Pretreatment Strategies for Near-Infrared Spectroscopy Calibration Development of Unground and Ground Compound FeedingstuffsApplied Spectroscopy, 2006
- Content uniformity and tablet hardness testing of intact pharmaceutical tablets by near infrared spectroscopyAnalytica Chimica Acta, 2006
- Transfer of Multivariate Calibrations between Four Near-Infrared Spectrometers Using Orthogonal Signal CorrectionAnalytical Chemistry, 2004
- Near-infrared spectroscopy and multivariate calibration for the quantitative determination of certain properties in the petrochemical industryTrAC Trends in Analytical Chemistry, 2002
- New Classical Least-Squares/Partial Least-Squares Hybrid Algorithm for Spectral AnalysesApplied Spectroscopy, 2001
- New Prediction-Augmented Classical Least-Squares (PACLS) Methods: Application to Unmodeled InterferentsApplied Spectroscopy, 2000
- Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopyAnalytica Chimica Acta, 1998
- Genetic Algorithm-Based Protocol for Coupling Digital Filtering and Partial Least-Squares Regression: Application to the Near-Infrared Analysis of Glucose in Biological MatricesAnalytical Chemistry, 1996
- A Statistical View of Some Chemometrics Regression ToolsTechnometrics, 1993
- Computer Aided Design of ExperimentsTechnometrics, 1969