Optimizing Flux Capacity of Dead-end Filtration Membranes by Controlling Flow with Pulse Width Modulated Periodic Backflush
Open Access
- 21 January 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Abstract
Standard dead-end sample filtration is used to improve sample purity, but is limited as particle build-up fouls the filter, leading to reduced recovery. The fouling layer can be periodically cleared with backflush algorithms applied through a customized fluidic actuator using variable duty cycles, significantly improving particulate recovery percentage. We show a Pulse Width Modulation (PWM) process can periodically backflush the filter membrane to repeatedly interrupt cake formation and reintegrate the fouling layer into the sample, improving net permeate flux per unit volume of sample by partially restoring filter flux capacity. PWM flow for 2.19 um (targeted) and 7.32 um (untargeted) polystyrene microbeads produced 18-fold higher permeate concentration, higher recovery up to 68.5%, and an 8-fold enrichment increase, compared to a uniform flow. As the duty cycle approaches 50%, the recovery percentage monotonically increases after a critical threshold. Further, we developed and validated a mathematical model to determine that fast, small-volume backflush pulses near 50% duty cycle yield higher recovery by decreasing fouling associated with the cake layer. Optimized PWM flow was then used to purify custom particles for immune activation, achieving 3-fold higher recovery percentage and providing a new route to improve purification yields for diagnostic and cellular applications.Keywords
This publication has 31 references indexed in Scilit:
- Stiffness Dependent Separation of Cells in a Microfluidic DevicePLOS ONE, 2013
- Effects of Microparticle Size and Fc Density on Macrophage PhagocytosisPLOS ONE, 2013
- Bifunctional Janus Microparticles with Spatially Segregated ProteinsLangmuir, 2012
- Particle sorting using a porous membrane in a microfluidic deviceLab on a Chip, 2010
- Microfluidic chip for blood cell separation and collection based on crossflow filtrationSensors and Actuators B: Chemical, 2008
- A new approach to backwash initiation in membrane systemsJournal of Membrane Science, 2006
- Design of a generic control system for optimising back flush durations in a submerged membrane hybrid reactorJournal of Membrane Science, 2005
- Optimisation of a back-flush sequence for zeolite microfiltrationJournal of Membrane Science, 2000
- The effect of oscillatory flow on crossflow microfiltration of beer in a tubular mineral membrane system – Membrane fouling resistance decrease and energetic considerationsJournal of Membrane Science, 1999
- Effect of transmembrane pressure pulsing on concentration polarizationJournal of Membrane Science, 1992