Abstract
Purpose: To evaluate in-vivo thrombus compressibility in abdominal aortic aneurysms (AAAs) to hopefully shed light on the biomechanical importance of intraluminal thrombus. Methods: Dynamic electrocardiographically-gated computed tomographic angiography was performed in 17 AAA patients (15 men; mean age 73 years, range 69–76): 11 scheduled for surgical repair and 6 under routine surveillance. The volumes of intraluminal thrombus, the lumen, and the total aneurysm were quantified for each phase of the cardiac cycle. Thrombus compressibility was defined as the percent change in thrombus volume between diastole and peak systole. Continuous data are presented as medians and interquartile ranges (IQR). Results: A substantial interpatient variability was observed in thrombus compressibility, ranging from 0.4% to 43.6% (0.2 to 13.5 mL, respectively). Both thrombus and lumen volumes varied substantially during the cardiac cycle. As lumen volume increased (5.2%, IQR 2.8%–8.8%), thrombus volume decreased (3.0%, IQR 1.0%–4.6%). Total aneurysm volume remained relatively constant (1.3%, IQR 0.4–1.9%). Changes in lumen volume were inversely correlated with changes in thrombus volume (r=–0.73; p=0.001). Conclusion: In-vivo thrombus compressibility varied from patient to patient, and this variation was irrespective of aneurysm size, pulse pressure, and thrombus volume. This suggests that thrombus might act as a biomechanical buffer in some, while it has virtually no effect in others. Whether differences in thrombus compressibility alter the risk of rupture will be the focus of future research.Keywords
This publication has 23 references indexed in Scilit:
- Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loadsJournal of Vascular Surgery, 2008
- Who Should We Operate On and How Do We Decide: Predicting Rupture and Survival in Patients with Aortic AneurysmSeminars in Vascular Surgery, 2007
- Non-linear viscoelastic behavior of abdominal aortic aneurysm thrombusBiomechanics and Modeling in Mechanobiology, 2007
- Guidelines for the treatment of abdominal aortic aneurysms: Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular SurgeryJournal of Vascular Surgery, 2003
- Long-Term Outcomes of Immediate Repair Compared with Surveillance of Small Abdominal Aortic AneurysmsNew England Journal of Medicine, 2002
- Mechanical Properties and Microstructure of Intraluminal Thrombus From Abdominal Aortic AneurysmJournal of Biomechanical Engineering, 2001
- Risk Factors for Aneurysm Rupture in Patients Kept Under Ultrasound SurveillanceAnnals of Surgery, 1999
- Mortality results for randomised controlled trial of early elective surgery or ultrasonographic surveillance for small abdominal aortic aneurysmsThe Lancet, 1998
- Rupture in small abdominal aortic aneurysmsJournal of Vascular Surgery, 1998
- Computed tomography scanning findings associated with rapid expansion of abdominal aortic aneurysmsJournal of Vascular Surgery, 1994