171 Yb optical lattice clock with uncertainty below 5×10 −18
Open Access
- 12 March 2026
- journal article
- Published by IOP Publishing in Metrologia
- Vol. 63 (2) , 025004
Abstract
We report improved performance of the 171 Yb optical lattice clocks at East China Normal University, achieving a total uncertainty of 4.4×10 −18 for the Yb2 clock through high-precision synchronous frequency comparisons with the similar Yb1 clock. A 578 nm laser for the 1 S 0 – 3 P 0 clock transition is cavity-stabilized using a newly developed ultra-stable laser system, featuring a reduced thermal-noise limit compared to its predecessor. Through systematic optimization, including suppression of technical noise in the laser system and detailed evaluation of frequency shifts, such as collision, blackbody radiation, lattice, and Zeeman shifts, we achieved stable clock-transition spectra for the m F = ± 1/2 spin states using 400 ms interrogation pulses, obtaining a Fourier-limited linewidth of 2 Hz. Based on these optimizations, synchronous comparisons between two 171 Yb clocks enable a fractional frequency instability for each clock to average at a rate of 2.0×10 −16 / τ , reaching 1.9 − 0.4 + 1.2 ×10 −18 at 8000 s, which provides the resolution necessary for high-precision systematic evaluation. Furthermore, a complementary asynchronous comparison accounting for the Dick noise yields an instability of 4.0×10 −18 at 8000 s. The combination of these high-precision comparisons and rigorous frequency shift evaluations validates the total systematic uncertainty below 5×10 −18 .Keywords
Funding Information
- Program of Shanghai Academic Research Leader (12XD1402400)
- National Key Research and Development Program of China (2016YFA0302103, 2017YFF0212003, and 2016YFB050160)
- National Natural Science Foundation of China (11134003)
- Shanghai Municipal Science and Technology Major Project (2019SHZDZX01)
This publication has 47 references indexed in Scilit:
- A lab-based test of the gravitational redshift with a miniature clock networkNature Communications, 2023
- Multiple strategies for evaluating the uncertainty of blackbody radiation frequency shift in an optical clockMeasurement, 2023
- Test of general relativity by a pair of transportable optical lattice clocksNature Photonics, 2020
- Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocksNature Photonics, 2019
- Ultrastable optical clock with two cold-atom ensemblesNature Photonics, 2016
- Towards a redefinition of the second based on optical atomic clocksComptes Rendus. Physique, 2015
- Systematic evaluation of an atomic clock at 2 × 10−18 total uncertaintyNature Communications, 2015
- Cryogenic optical lattice clocksNature Photonics, 2015
- An optical lattice clock with accuracy and stability at the 10−18 levelNature, 2014
- Frequency comparison of optical lattice clocks beyond the Dick limitNature Photonics, 2011