Influence of C-Trap Ion Accumulation Time on the Detectability of Analytes in IR-MALDESI MSI
- 6 October 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (20) , 10483-10490
Abstract
Laser desorption followed by post electrospray ionization requires synchronized timing of the key events (sample desorption/ionization, mass spectrometry analysis, and sample translation) necessary to conduct mass spectrometry imaging (MSI) with adequate analyte sensitivity. In infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI analyses, two laser pulses are used for analysis at each volumetric element, or voxel, of a biological sample and ion accumulation in the C-trap exceeding 100 ms is necessary to capture all sample-associated ions using an infrared laser with a 20 Hz repetition rate. When coupled to an Orbitrap-based mass spectrometer like the Q Exactive Plus, this time window for ion accumulation exceeds dynamically controlled trapping of samples with comparable ion flux by Automatic Gain Control (AGC), which cannot be used during MSI analysis. In this work, a next-generation IR-MALDESI source has been designed and constructed that incorporates a mid-infrared OPO laser capable of operating at 100 Hz and allows requisite C-trap inject time during MSI to be reduced to 30 ms. Analyte detectability of the next-generation IR-MALDESI integrated source has been evaluated as a function of laser repetition rate (100–20 Hz) with corresponding C-trap ion accumulation times (30–110 ms) in both untargeted and targeted analysis of biological samples. Reducing the C-trap ion accumulation time resulted in increased ion abundance by up to 3 orders of magnitude for analytes ranging from xenobiotics to endogenous lipids, and facilitated the reduction of voxel-to-voxel variability by more than 3-fold.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (P30AI50410, R01AI111891, U19AI096113)
- North Carolina State University
- National Institute of General Medical Sciences (R01GM087964)
- W.M. Keck Foundation
This publication has 49 references indexed in Scilit:
- Mass spectrometry imaging for drugs and metabolitesJournal of Proteomics, 2011
- Study of the ionization mechanism in hybrid laser based desorption techniquesThe Analyst, 2010
- Ovarian Adenocarcinomas in the Laying Hen and Women Share Similar Alterations in p53, ras, and HER-2/neuCancer Prevention Research, 2009
- Interferences and contaminants encountered in modern mass spectrometryAnalytica Chimica Acta, 2008
- Protein and peptides in pictures: Imaging with MALDI mass spectrometryProteomics, 2008
- ProteoWizard: open source software for rapid proteomics tools developmentBioinformatics, 2008
- Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry for the Investigation of Proteins and PeptidesAnnual Review of Analytical Chemistry, 2008
- LMSD: LIPID MAPS structure databaseNucleic Acids Research, 2006
- Imaging mass spectrometry: fundamentals and applications to drug discoveryDrug Discovery Today, 2005
- Molecular imaging in drug discovery and developmentNature Reviews Drug Discovery, 2003