Interfacial Bond Behavior of High Strength Concrete Filled Steel Tube after Exposure to Elevated Temperatures and Cooled by Fire Hydrant
Open Access
Abstract
For the engineering structure in case of fire, a fire hydrant is generally used for extinguishing the fire. This paper presents an experimental investigation on interfacial bond behavior of high-strength concrete-filled steel tube (HSCFST) after exposure to elevated temperatures and cooled by fire hydrant using the pull-out test of 22 specimens. According to the experimental study, the failure mechanism of HSCFST exposed to elevated temperatures and water-cooling (ETWC) was revealed, the influence of various parameters on the bond behavior was analyzed, and the calculation formula of the bond strength of HSCFST subjected to ETWC was put forward. The results show that the load-slip curves of the loading end and the free end of the specimen are basically similar, and can be divided into three types of typical curves. In the push out test, the strain on the outer surface of the steel tube is exponentially distributed with its distance from the loading end. After ETWC exposure, the bond strength of the specimen is less affected by the concrete strength, which is inversely proportional to the anchorage length, and it is basically stable after the constant temperature duration is longer than 60 min. With the increase of the maximum temperature, the ultimate bond strength increases first, then decreases and then increases, and the residual bond strength increases first and then decreases. Besides, the study indicate that cooling method has significant influence on the bond behavior, compared with natural cooling specimens, the ultimate bond strength, residual bond strength, and shear bond stiffness of water-cooling specimens are smaller, and the interfacial energy dissipation capacity is larger.Keywords
This publication has 12 references indexed in Scilit:
- High temperature and residual properties of reactive powder concrete – A reviewConstruction and Building Materials, 2017
- Predicting the axial load capacity of high-strength concrete filled steel tubular columnsSteel and Composite Structures, 2015
- Static behaviour of multi-row stud shear connectors in high- strength concreteSteel and Composite Structures, 2014
- Numerical analysis of high-strength concrete-filled steel tubular slender beam-columns under cyclic loadingJournal of Constructional Steel Research, 2014
- High performance concrete under elevated temperaturesConstruction and Building Materials, 2013
- Load-reversed push-out tests on rectangular CFST columnsJournal of Constructional Steel Research, 2013
- Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columnsJournal of Constructional Steel Research, 2011
- Mechanical properties of normal and high strength concretes subjected to high temperatures and using image analysis to detect bond deteriorationsConstruction and Building Materials, 2010
- Incremental collapse threshold for pushout resistance of circular concrete filled steel tubular columnsJournal of Constructional Steel Research, 2010